Ultra high field MR imaging (≥7 T) of deeply located targets in the body is facing some radiofrequency‐field related challenges: interference patterns, reduced penetration depth, and higher Specific Absorbtion Ratio (SAR) levels. These can be alleviated by redesigning the elements of the transmit or transceive array. This is because at these high excitation field (B1) frequencies, conventional array element designs may have become suboptimal. In this work, an alternative design approach is presented, regarding coil array elements as antennas. Following this approach, the Poynting vector of the element should be oriented towards the imaging target region. The single‐side adapted dipole antenna is a novel design that fulfills this requirement. The performance of this design as a transmit coil array element has been characterized by comparison with three other, more conventional designs using finite difference time domain (FDTD) simulations and B +1 measurements on a phantom. Results show that the B +1 level at the deeper regions is higher while maintaining relatively low SAR levels. Also, the B +1 field distribution is more symmetrical and more uniform, promising better image homogeneity. Eight radiative antennas have been combined into a belt‐like surface array for prostate imaging. T1‐weighted (T1W) and T2‐weighted (T2W) volunteer images are presented along with B +1 measurements to demonstrate the improved efficiency. Magn Reson Med, 2011. © 2011 Wiley Periodicals, Inc.
This study demonstrates the feasibility of the noninvasive determination of important biomarkers of human (breast) tumor metabolism using high-field (7-T) MRI and MRS. (31) P MRSI at this field strength was used to provide a direct method for the in vivo detection and quantification of endogenous biomarkers. These encompass phospholipid metabolism, phosphate energy metabolism and intracellular pH. A double-tuned, dual-element transceiver was designed with focused radiofrequency fields for unilateral breast imaging and spectroscopy tuned for optimized sensitivity at 7 T. T(1) -weighted three-dimensional MRI and (1) H MRS were applied for the localization and quantification of total choline compounds. (31) P MRSI was obtained within 20 min per subject and mapped in three dimensions over the breast with pixel volumes of 10 mL. The feasibility of monitoring in vivo metabolism was demonstrated in two patients with breast cancer during neoadjuvant chemotherapy, validated by ex vivo high-resolution magic angle spinning NMR and compared with data from an age-matched healthy volunteer. Concentrations of total choline down to 0.4 mM could be detected in the human breast in vivo. Levels of adenosine and other nucleoside triphosphates, inorganic phosphate, phosphocholine, phosphoethanolamine and their glycerol diesters detected in glandular tissue, as well as in tumor, were mapped over the entire breast. Altered levels of these compounds were observed in patients compared with an age-matched healthy volunteer; modulation of these levels occurred in breast tumors during neoadjuvant chemotherapy. To our knowledge, this is the first comprehensive MRI and MRS study in patients with breast cancer, which reveals detailed information on the morphology and phospholipid metabolism from volumes as small as 10 mL. This endogenous metabolic information may provide a new method for the noninvasive assessment of prognostic and predictive biomarkers in breast cancer treatment.
A noise figure and noise parameter measurement system was developed that consists of a combination spectrum and network analyzer, preamplifier, programmable power supply, noise source, tuning board, and desktop computer. The system uses the Y-factor method for noise figure calculation and allows calibrations to correct for a decrease in excess noise ratio between the noise source and device under test, second stage (system) noise, ambient temperature variations, and available gain of the device under test. Noise parameters are extracted by performing noise figure measurements at several source impedance values obtained by adjusting an electronically controlled tuner. Results for several amplifiers at 128 MHz and 200 MHz agree with independent measurements and with the corresponding datasheets. With some modifications, the system was also used to characterize the noise figure of MRI preamplifiers in strong static magnetic fields up to 9.4 T. In most amplifiers tested the gain was found to be reduced by the magnetic field, while the noise figure increased. These changes are detrimental to signal quality (SNR) and are dependent on the electron mobility and design of the amplifier's semiconductor devices. Consequently, gallium arsenide (GaAs) field-effect transistors are most sensitive to magnetic fields due to their high electron mobility and long, narrow channel, while silicon-germanium (SiGe) bipolar transistor amplifiers are largely immune due to their very thin base.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.