Grassland communities of arid western North America are often characterized by a seasonal increase in ambient temperature and evaporative demand and a corresponding decline in soil moisture availability. As the environment changes, particular species could respond differently, which should be reflected in a number of physiological processes. Carbon isotope discrimination varies during photosynthetic activity as a function of both stomatal aperture and the biochemistry of the fixation process, and provides an integrated measure of plant response to seasonal changes in the environment. We measured the seasonal course of carbon isotope discrimination in 42 grassland species to evaluate changes in gas exchange processes in response to these varying environmental factors. The seasonal courses were then used to identify community-wide patterns associated with life form, with phenology and with differences between grasses and forbs. Significant differences were detected in the following comparisons: (1) Carbon isotope discrimination decreased throughout the growing season; (2) perennial species discriminated less than annual species; (3) grasses discriminated less than forbs; and (4) early flowering species discriminated more than the later flowering ones. These comparisons suggested that (1) species active only during the initial, less stressful months of the growing season used water less efficiently, and (2) that physiological responses increasing the ratio of carbon fixed to water lost were common in these grassland species, and were correlated with the increase in evaporative demand and the decrease in soil moisture.
Abstract. For more than two decades, research groups in hydrology, ecology, soil science, and biogeochemistry have performed cryogenic water extractions (CWEs) for the analysis of δ2H and δ18O of soil water. Recent studies have shown that extraction conditions (time, temperature, and vacuum) along with physicochemical soil properties may affect extracted soil water isotope composition. Here we present results from the first worldwide round robin laboratory intercomparison. We test the null hypothesis that, with identical soils, standards, extraction protocols, and isotope analyses, cryogenic extractions across all laboratories are identical. Two standard soils with different physicochemical characteristics along with deionized (DI) reference water of known isotopic composition were shipped to 16 participating laboratories. Participants oven-dried and rewetted the soils to 8 and 20 % gravimetric water content (WC), using the deionized reference water. One batch of soil samples was extracted via predefined extraction conditions (time, temperature, and vacuum) identical to all laboratories; the second batch was extracted via conditions considered routine in the respective laboratory. All extracted water samples were analyzed for δ18O and δ2H by the lead laboratory (Global Institute for Water Security, GIWS, Saskatoon, Canada) using both a laser and an isotope ratio mass spectrometer (OA-ICOS and IRMS, respectively). We rejected the null hypothesis. Our results showed large differences in retrieved isotopic signatures among participating laboratories linked to soil type and soil water content with mean differences compared to the reference water ranging from +18.1 to −108.4 ‰ for δ2H and +11.8 to −14.9 ‰ for δ18O across all laboratories. In addition, differences were observed between OA-ICOS and IRMS isotope data. These were related to spectral interferences during OA-ICOS analysis that are especially problematic for the clayey loam soils used. While the types of cryogenic extraction lab construction varied from manifold systems to single chambers, no clear trends between system construction, applied extraction conditions, and extraction results were found. Rather, observed differences in the isotope data were influenced by interactions between multiple factors (soil type and properties, soil water content, system setup, extraction efficiency, extraction system leaks, and each lab's internal accuracy). Our results question the usefulness of cryogenic extraction as a standard for water extraction since results are not comparable across laboratories. This suggests that defining any sort of standard extraction procedure applicable across laboratories is challenging. Laboratories might have to establish calibration functions for their specific extraction system for each natural soil type, individually.
A quantitative method for cryogenically sampling atmospheric water vapor on the temporal scale of 10 to 15 min in the field or laboratory is described. The sample apparatus is lightweight, affordable, and easy to assemble. The method allows for H2O:CO2 equilibration within the same sampling tubes and hence increases turnaround time for delta18O analysis. Quantitative analysis in the laboratory showed recovery of a vaporized, known, 18O water standard to 0.2 per thousand precision.
Isotope ratio analyses of atmospheric CO(2) at natural abundance have significant potential for contributing to our understanding of photosynthetic and respiration processes in forest ecosystems. Recent advances in isotope ratio mass spectrometry allow for rapid, on-line analysis of small volumes of CO(2) in air, and open new research opportunities at the ecophysiological, whole-organism, and atmospheric levels. Among the immediate applications are the carbon and oxygen isotope ratio analyses of carbon dioxide in atmospheric air. Routine analysis of carbon dioxide in air volumes of approximately 50-300 &mgr;l is accomplished by linking a commercially available, trace gas condenser and gas chromatograph to an isotope ratio mass spectrometer operated in continuous-flow mode. Samples collected in the field are stored in either gas-tight syringes or 100-ml flasks. The small sample volume required makes it possible to subsample the air in flasks for CO(2) and then to sample the remaining air volume for the analysis of the isotopic composition of either methane or nitrous oxide. Reliable delta(13)C and delta(18)O values can be obtained from samples collected and stored for 1-3 days. Longer-term storage, on the order of weeks, is possible for delta(13)C measurements without drift in the isotope ratio signal, and should also be possible for delta(18)O measurements. When linked with an infrared gas analyzer, pump and flask sampling system, it is feasible to sample CO(2) extensively in remote forest locations. The air-sampling system was used to measure the isotope ratios of atmospheric CO(2) and to conduct a regression analysis of the relationship between these two parameters. From the regression, we calculated the delta(13)C of ecosystem respiration of four coniferous ecosystems along a precipitation gradient in central Oregon. The ecosystems along the coast-to-interior Oregon (OTTER) gradient are dominated by spruce-hemlock forests at the wet, coastal sites (> 200 cm precipitation annually) to juniper woodlands (20 cm precipitation) at the interior, dry end of the transect. The delta(13)C values of ecosystem respiration along this transect differed by only 1.3 per thousand (range of -25.2 to -23.9 per thousand ) during August at the peak of the summer drought. Following autumn rains in September, the delta(13)C of ecosystem respiration in the four stands decreased; overall the difference in the carbon isotope ratio of ecosystem respiration among sites increased to 3.9 per thousand (-26.8 to -22.9 per thousand ).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.