In order to evaluate and report the personal doses in terms of personal dose equivalent, the performance of the CaSO(4):Dy based thermoluminescence dosemeter (TLD) badge used for countrywide personnel monitoring in India is investigated using monoenergetic and narrow spectrum radiation qualities equivalent to those given in ISO standards. Algorithms suitable for evaluating H(p)(10) and H(p)(0.07) within +/- 30 % are developed from the responses of dosemeter elements/discs under different filters for normal as well as angular irradiation conditions using these beams. The algorithm is tested for TLD badges irradiated to mixtures of low- and high-energy ((137)Cs) beams in various proportions. The paper concludes with the results of test of algorithm by evaluation of badges used in the IAEA/RCA intercomparison studies and discussion on inherent limitations.
In the present study, a method of identifying abnormal glow curves to electronically screen the glow curves of TL readout is presented. The method is based on the fact that the shape of an abnormal glow curve differs from the shape of a normal one. A few criteria for defining the normal shape of glow curves are arrived at by analysing the glow curves of dosemeters exposed to various doses in laboratory conditions and read at different elapsed time post irradiation. About 300 glow curves of dosemeters used for monthly monitoring were analysed as per these criteria and the effectiveness of the method is observed for total counts as low as 150 µSv equivalent.
In view of the recommendations of International Commission on Radiological Protection for reduction of the occupational annual dose limit for eye lens from 150 mSv to 20 mSv/y, questions have been raised on the adequacy of monitoring for the quantities Hp(10) and Hp(0.07). As an immediate requirement, in the present situation, where there is no exclusive eye lens dosemeter in India, the existing chest TLD badge was modified to be used as head badge (head dosemeter) by including a strap to enable wearing on the forehead. In order to estimate the eye lens dose in terms of the operational quantity Hp(3), the prevalent algorithm of chest badge was also modified. The modified algorithm was applied to estimate Hp(3) for dosemeters irradiated to various beta and photon radiations including mixtures. The Q values (estimated/delivered dose equivalent) were found to be within ±20% for most of the photon beams.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.