Purpose Most studies evaluating artificial intelligence (AI) models that detect abnormalities in neuroimaging are either tested on unrepresentative patient cohorts or are insufficiently well-validated, leading to poor generalisability to real-world tasks. The aim was to determine the diagnostic test accuracy and summarise the evidence supporting the use of AI models performing first-line, high-volume neuroimaging tasks. Methods Medline, Embase, Cochrane library and Web of Science were searched until September 2021 for studies that temporally or externally validated AI capable of detecting abnormalities in first-line computed tomography (CT) or magnetic resonance (MR) neuroimaging. A bivariate random effects model was used for meta-analysis where appropriate. This study was registered on PROSPERO as CRD42021269563. Results Out of 42,870 records screened, and 5734 potentially eligible full texts, only 16 studies were eligible for inclusion. Included studies were not compromised by unrepresentative datasets or inadequate validation methodology. Direct comparison with radiologists was available in 4/16 studies and 15/16 had a high risk of bias. Meta-analysis was only suitable for intracranial hemorrhage detection in CT imaging (10/16 studies), where AI systems had a pooled sensitivity and specificity 0.90 (95% confidence interval [CI] 0.85–0.94) and 0.90 (95% CI 0.83–0.95), respectively. Other AI studies using CT and MRI detected target conditions other than hemorrhage (2/16), or multiple target conditions (4/16). Only 3/16 studies implemented AI in clinical pathways, either for pre-read triage or as post-read discrepancy identifiers. Conclusion The paucity of eligible studies reflects that most abnormality detection AI studies were not adequately validated in representative clinical cohorts. The few studies describing how abnormality detection AI could impact patients and clinicians did not explore the full ramifications of clinical implementation.
The posterior slope of the tibial plateau is an important feature to preserve during knee replacement. The correct slope aids in the amount of flexion and determines if the knee will be loose on flexion. This is a study on the posterior tibial plateau slope based on preoperative and postoperative radiographs of 100 consecutive patients who had total knee replacements. The average posterior slope of the tibia plateau was 10.1 degrees. There is a tendency for patients with higher pre-operative posterior tibial plateau slope to have higher post-operative posterior tibial plate slope.
We evaluated the efficacy of a cement gun to improve the depth of cement penetration in total knee arthroplasty. Ninety-one consecutive patients from two hospitals were recruited for this study. For Group I cement was applied to the tibial baseplate and the proximal tibia with fingers. Group 2 had similar application of cement to the tibial baseplate but cement was pressurized into the proximal tibia using a cement gun.. The knee was kept extended until the cement hardened. Standard post-operative x-rays were reviewed to assess cement penetration into the proximal tibia. The mean cement penetration was 2.1 mm in Group 1 and 3.1 mm in Group 2 and the difference was statistically significant. The use of the cement gun improves cement penetration into the proximal tibia and facilitates early stability of the implant fixation to the bone.
INTRODUCTION Biochemical verification of smoking status prior to recruitment into smoking cessation trials is widely used to confirm smoking status, most commonly using exhaled carbon monoxide (CO). There is variation in the level of CO used as a biochemical inclusion criterion, and thus the possibility for people reporting to be current smokers to be incorrectly excluded from trials. METHODS As part of the Cessation of Smoking Trial in the Emergency Department, people attending the Emergency Department (ED) who reported being current daily smokers underwent CO testing to confirm eligibility. Elective semi-structured interviews were undertaken with the researchers who recruited participants. As part of the interviews, researchers were asked their views and experiences with CO testing. RESULTS Of the 1320 participants who reported being current daily smokers and underwent CO testing, 300 (22.7%) blew a CO reading of 7 ppm or less and were excluded from taking part. Possible explanations offered by researchers for participants blowing low CO readings were (1) long wait times in the ED, therefore a long period having elapsed since people had last smoked and (2) patients having reduced smoking for the period before the ED attendance due to ill health. CONCLUSIONS Biochemical verification has the potential to improve internal validity of smoking cessation for inclusion in trials, but at the cost of reduced generalisability through exclusion of participants who would receive the intervention if it were implemented in practice. We would recommend researchers carefully consider whether it is appropriate and necessary to include biochemical verification as an inclusion criterion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.