Background:The correct position of the endotracheal tube is confirmed by various modalities, most of which are not entirely reliable. Ultrasound is now increasingly available to anesthesiologists in the operating theater and is an attractive alternative. To investigate the usefulness of sonography in identifying the correct tracheal tube position in human cadavers.Materials and Methods:Endotracheal tubes placed randomly into trachea or esophagus was identified with a linear ultrasound probe placed transversely just above the suprasternal notch by a single anesthesiologist.Results:Of the 100 intubations performed at random, 99 were correctly identified to give a sensitivity of 100% and a specificity of 97.9%.Conclusion:Sonography is a useful technique to identify correct position of the tracheal tube.
Background:Spinal cord injury resulting from spinal anesthesia is a rare, but an alarming scenario. The most likely cause is believed to be misjudged level of intervertebral space (IVS). We evaluated the accuracy of palpation method to locate IVS with the ultrasonography.Materials and Methods:A total of 109 patients undergoing spinal anesthesia were included in this observational, double-blind study. First anesthesiologist was asked to mark IVS using palpation method. It was followed by ultrasonographic assessment by another anesthesiologist who was unaware of the level estimated for the mark. We evaluated the accuracy of palpation method in sitting and lateral position as well as the impact of the anesthesiologist's experience (Trainee/Consultant).Statistical Analysis Used:Association between the gender, anthropometric parameters, type of anesthesiologists assessing the IVS, and the level of agreement were identified using Chi-square test. The agreement between palpation method and ultrasound assessment of IVS was analyzed using kappa statistic. P < 0.05 was defined as statistical significance.Results:The IVS located by palpation method was in agreement with ultrasound location in 37.14% of the patients. There were no statistically significant differences found in terms of demographic data (sex, age, height, weight, or body mass index [BMI]) between agreement and disagreement group. The rate of errors was found to be significantly higher (P = 0.01) among the trainees (74.51%) than the consultants (51.86%). The rate of errors was not different between the sitting and lateral position. The frequency of errors was more common in cephalad direction (53.31.5%) compared to caudal direction (9.52%). The misidentified spaces were as high as three spaces above the intended space while in caudal direction it differed by only one space.Conclusion:The accuracy of palpation method controlled by ultrasound is 37.14% and differs by 1-3 IVS in cephalad direction (53.31%). The accuracy is affected by anesthesiologist's experience but remains unaffected by age, sex height, BMI, and patient positioning.
The patients with complicated congenital heart diseases are reaching adulthood with advances in corrective surgeries and medical management. Impact of anesthetic agents on complex cardiac and extra cardiac anomalies and presence of previous palliative procedures can be a challenge for the anesthesiologist perioperatively, while these patients present for cardiac/noncardiac surgeries. We report the perioperative management of a patient with ventricular septal defect, dextrocardia, pulmonary hypertension, and situs inversus who underwent a successful hernioplasty and hydrocelectomy with a combined spinal epidural anesthesia. This discussion relates to the anesthetic management in such conditions with a special reference to Kartagener's syndrome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.