This study aimed to analyze the average air temperature data estimated by ERA5-Land reanalysis over 10 years (01/01/2011 to 12/31/2020), based on data from 12 automatic weather stations located in different cities in the state of Pernambuco, northeast of Brazil. For more careful evaluation, the average air temperature data were stratified by mesoregions of the state. ERA5-Land reanalysis data were validated using statistical indices that evaluated the accuracy. The average air temperature estimated by ERA5-Land reanalysis agree well with weather stations in almost the entire state of Pernambuco. The highest accuracy of the average air temperature estimated by ERA5-Land occurred in the city of Ibimirim (R2 = 0.98), while the lowest accuracy was measured in the city of Caruaru ( R2 = 0.57). Rootmean-square error (RMSE) generated by the ERA5-Land reanalysis was lower than 0.60 °C in most Pernambuco. The highest RMSE of ERA5-Land for average air temperature was calculated using data from the city of Caruaru (1.11 °C), whereas the lowest RMSE was obtained with data from the city of Recife (0.41 °C). According to mean bias errors, (MBE) the ERA5-Land underestimated the average air temperature data compared to automatic weather stations data, especially in Ouricuri, which had the highest underestimation (−0.80 °C). On the other hand, among the municipalities where ERA5-Land overestimated the temperature values, the highest overestimation was identified in Garanhuns (0.35 °C). Therefore, based on the results of this study, ERA5-Land reanalysis successfully estimated the average air temperature for the state of Pernambuco.
A determinação de parâmetros biofísicos, tais como o Índice de Vegetação por Diferença Normalizada (NDVI) e a Temperatura de superfície (Ts), são de extrema importância para estudos de mudanças climáticas nos ambientes em geral. Com isso, o objetivo do presente estudo foi analisar a variabilidade espaço-temporal das variáveis biofísicas de NDVI e Ts, utilizando produtos de sensoriamento remoto, em área heterogênea, com predominância de cobertura vegetal de Caatinga, associando as respostas das variações a eventos sazonais de precipitação (P) e temperatura média diária do ar (Tar). Os resultados obtidos mostraram claramente o comportamento da vegetação de Caatinga mediante a distribuição temporal da precipitação pluvial, apresentando resultados de NDVI maiores para os períodos com maior disponibilidade hídrica e de Ts menor, devido a influência do desenvolvimento de biomassa verde sobre essas duas variáveis.
As águas subterrâneas no município de Pau dos Ferros, a cada dia são mais exploradas para o abastecimento residencial, como também para o comércio local e abastecimento animal. A demanda por água, devido a longa estiagem que assola, gera uma preocupação sobre o futuro dos recursos hídricos. Entretanto, a população faz sua exploração de maneira desordenada sem se preocupar com a quantidade e a qualidade dessas águas, visto que, a recarga desses mananciais não vem acontecendo devido à estiagem de chuvas e o aumento da concentração de minerais e outros sólidos nos poços de captação, os quais podem limitar seus múltiplos usos e causar doenças futuras a população. Desse modo, este trabalho objetivou avaliar a qualidade das águas subterrâneas na cidade de Pau dos Ferros-RN, em que foram efetuadas coletas de água de 18 poços tubulares na área urbana do município, sendo analisados parâmetros físicos e químicos em laboratório da Universidade Federal Rural do Semiárido. Os resultados das análises mostraram a ocorrência de poços com altos teores de cálcio e magnésio, aumentando assim a condutividade elétrica, a dureza da água e consequentemente deixando-a salobra. Quanto a distribuição espacial, o poço 12 localizado no bairro São Judas Tadeu apresentou os níveis mais altos de sais de cálcio e magnésio. Os órgãos responsáveis pela gestão das águas subterrâneas deveriam promover políticas de manejo e conscientização desses recursos, a fim de promover o uso racional destas. Palavras-chave: Estiagem. Mananciais. Recursos hídricos.
AVALIAÇÃO DE DESEMPENHO DO MICROASPERSOR EM LINHA LATERAL E SIMULAÇÃO MATEMÁTICA DE SEU GRADIENTE DE ENERGIA MADSON RAFAEL BARBALHO DA SILVA1; LÍVIA MARIA CAVALCANTE SILVA1; ANA CLÁUDIA DAVINO DOS SANTOS1; FABIANO SIMPLICIO BEZERRA1; CAIO SÉRGIO PEREIRA DE ARAÚJO1 E MANASSÉS MESQUITA DA SILVA1 1 Departamento de Engenharia Agrícola, Universidade Federal Rural de Pernambuco, Dom Manuel de Medeiros, s/n, Dois Irmãos, 52171-900, Recife, Pernambuco, Brasil. E-mail:madsonbarbalhoagronomo@gmail.com; cavalcants.livia@gmail.com; aclaudiadavino@gmail.com; fabianoagro14@gmail.com; caiosergio.ufersa@gmail.com; manasses.ufrpe@gmail.com. 1 RESUMO Objetivou-se avaliar o desempenho do microaspersor Agropolo modelo MC20 em diferentes condições hidráulicas, gerando informações para um melhor dimensionamento de sistemas de microirrigação e manejo da água em áreas irrigadas. A condução do projeto hidráulico para simulação do gradiente de energia em linhas laterais, considerou-se informações determinadas através da escolha de componentes do projeto. Foram extraídos do catálogo comercial do fabricante os pares de valores referentes a vazão e a pressão e, a partir destes, gerou-se a curva vazão-pressão, onde a simulação foi feita pelo Método Algébrico - Christiansen (MA) e Método Iterativo (SBS) – Back-Step. Para ambos métodos o microaspersor se comportou de maneira semelhante, quando submetido a condições sugeridas pelo fabricante, num espaçamento entre emissores de 5,2 m, usando tubos de polietilenos de diâmetro interno de 13 mm e uma pressão de serviço de 20 mca, admitindo uma variação de 10% da pressão. Foram calculados os coeficientes de uniformidade de pressão (CUp) e de vazão (CUq), ambos com valores superiores à 95%, demonstrando a excelência no desempenho do emissor. Palavras-chave: hidráulica, modelagem matemática, coeficiente de descarga. SILVA, M. R. B.; SILVA, L. M. C.; SANTOS, A. C. D.; BEZERRA, F. S.; ARAUJO, C. S. P.; SILVA, M. M. PERFORMANCE EVALUATION OF THE SIDE LINE MICROSPARENT AND MATHEMATICAL SIMULATION OF ITS ENERGY GRADIENT 2 ABSTRACT The objective was to evaluate the performance of the Agropolo model MC20 microsprinkler under different hydraulic conditions, generating information for a better design of micro-irrigation systems and water management in irrigated areas. The conduction of the hydraulic project to simulate the energy gradient in lateral lines, considered information determined through the choice of project components. The pairs of values referring to flow and pressure were extracted from the manufacturer's commercial catalog and, from these, the flow-pressure curve was generated, where the simulation was performed using the Algebraic Method - Christiansen (MA) and Iterative Method (SBS) – Back-Step. For both methods, the microsprinkler behaved similarly, when subjected to conditions suggested by the manufacturer, in a spacing between emitters of 5.2 m, using polyethylene tubes with an internal diameter of 13 mm and a working pressure of 20 mca, admitting a 10% pressure variation. The uniformity of pressure (CUp) and flow (CUq) coefficients were calculated, both with values above 95%, demonstrating the excellence in the performance of the emitter. Keywords: hydraulic, mathematical modeling, discharge coefficient.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.