Calcium is an important molecule in a number of biological systems. Often these systems are signal transduction cascades involving molecules such as ATP. ATP activates second messengers which can interact with ion channels on the endoplasmic/sarcoplasmic reticulum resulting in the emptying of the intracellular calcium stores and an increase in cytosolic free calcium concentration ([Ca2+]c). Changes in [Ca2+]c can be influenced by external factors such as a static magnetic field (SMF). One hypothesis suggests that a SMF affects the cells through the radical pair mechanism. By reducing the number of antioxidant molecules like glutathione (GSH), the proportion of free radicals in the cells is increased and may lead to a greater probability of a biological response to a SMF. The purpose of this study was to determine if the [Ca2+]c response to ATP was affected by depletion of GSH by diethylmaleate (DEM) and the absence or presence of a 100 mT homogeneous SMF. Undifferentiated HL-60 cells were loaded with fura-2 AM. [Ca2+]c was measured in real time using a ratiometric fluorescence spectroscopy system. Various (DEM) ranging from 1 to 15 mM were added to deplete GSH. Cells were either exposed to sham or magnetic field (100 mT) for 13 min (780 s) and challenged with 1 microM ATP. The data show that [Ca2+]c was elevated following treatment with DEM with greater [Ca2+]c at higher [DEM]. The [Ca2+]c response to ATP was decreased as the DEM concentration increased. However, there was no effect of a 100 mT SMF on the average [Ca2+]c peak following ATP activation or the full width at half maximum (FWHM) of the [Ca2+]c response and recovery after ATP activation.
This study investigated whether glutathione depletion affected the sensitivity of HL-60 cells to static magnetic fields. The effect of Diethylmaleate (DEM) on static magnetic field induced changes in cytosolic free calcium concentration ([Ca(2+)](c)) was examined. Cells were loaded with a fluorescent dye and exposed to a uniform static magnetic field at a strength of 0 mT (sham) or 100 mT. [Ca(2+)](c) was monitored during field and sham exposure using a ratiometric fluorescence spectroscopy system. Cells were activated by the addition of ATP. Metrics extracted from the [Ca(2+)](c) time series included: average [Ca(2+)](c) during the Pre-Field and Field Conditions, peak [Ca(2+)](c) following ATP activation and the full width at half maximum (FWHM) of the peak ATP response. Comparison of each calcium metric between the sham and 100 mT experiments revealed the following results: average [Ca(2+)](c) measured during the Field condition was 53 +/- 2 nM and 58 +/- 2 nM for sham and 100 mT groups, respectively. Average FWHM was 51 +/- 3 s and 54 +/- 3 s for sham and 100 mT groups, respectively. An effect of experimental order on the peak [Ca(2+)](c) response to ATP in sham/sham experiments complicated the statistical analysis and did not allow pooling of the first and second order experiments. No statistically significant difference between the sham and 100 mT groups was observed for any of the calcium metrics. These data suggested that manipulation of free radical buffering capacity in HL-60 cells did not affect the sensitivity of the cells to a 100 mT static magnetic field.
Human exposure to magnetic fields, increased through use of new technologies like magnetic resonance imaging (MRI), has prompted investigations into possible effects of static magnetic fields (SMFs) on cellular processes. However, controversy still remains between many studies, which likely results from a lack of uniformity across experimental parameters, including the length of magnetic field exposure, the strength of the magnetic field, and the cell type or organism under investigation. The purpose of this research was to monitor effects of SMF exposure using real-time luminescence photometry. The study investigated the potential interaction of a 100 mT SMF on a heat shock protein (hsp70)/luciferase reporter construct in stably transfected NIH3T3 cells. Changes in heat shock promoter activation following 100 mT SMF exposure were analyzed and detected as bioluminescence in real-time. Two heat parameters were considered in combination with sham- and 100 mT-exposed experiments: no heat or 1,800 s heat. As expected, there was a significant increase in bioluminescence in response to 1,800 s of heat alone. However, no significant difference in average hsp70 promoter activation between sham and 100 mT experiments was observed for no heat or 1,800 s heat experiments. Therefore, a 100 mT SMF was shown to have no effect on the activation of the heat shock protein promoter during SMF exposure or when SMF exposure was combined with a heat insult.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.