We report a method for the assay of proteins at concentrations lower than 10(-)(10) M with as little as 200 amol of protein. High sensitivity is accomplished by derivatizing the ε-amino group of the protein's lysine residues with the fluorogenic dye 5-furoylquinoline-3-carboxaldehyde and use of a sheath flow cuvette fluorescence detector. Most proteins have a large number of lysine residues; therefore, a large number of fluorescent molecules can be attached to each protein molecule. In general, precolumn labeling improves sensitivity but degrades resolution due to the inhomogeneity of the reaction products from multiple labeling. However, we demonstrate that, through careful manipulation of the separation and reaction conditions, high sensitivity can be obtained without excessive loss in separation efficiency. Over 190 000 theoretical plates are obtained for fluorescently labeled ovalbumin.
The toxicity and efficacy of two oximes, HLö-7 and pyrimidoxime, were evaluated in mice and compared to those obtained with HI-6. HLö-7 and pyrimidoxime produced 24 h LD50 values of 356 and 291 mg/kg (i.p.), respectively. In combination with atropine (17.4 mg/kg, i.p.), HLö-7 was a very efficient therapy against poisoning by 3 x LD50 dose of soman, sarin and GF and 2 x LD50 dose of tabun with ED50 values of 12.4, 0.31, 0.32 and 25.2 mg/kg, respectively. In contrast, pyrimidoxime was a relatively poor therapy which resulted in ED50 values of greater than 150, 5.88, 100 and 71 mg/kg against poisoning by soman, sarin, GF and tabun, respectively. HLö-7 produced significant (p less than 0.05) reactivation of phosphorylated acetylcholinesterase, in vivo, resulting in 47, 38, 27 and 10% reactivation of sarin, GF, soman and tabun inhibited mouse diaphragm acetylcholinesterase, respectively. HLö-7 also antagonized sarin-induced hypothermia in mice suggesting that it reactivated central acetylcholinesterase. The potential of HLö-7 as a replacement oxime for the treatment of nerve agent poisoning is discussed.
On October 12, 2001, two envelopes containing Bacillus anthracis spores passed through a sorting machine in a postal facility in Washington, D.C. When anthrax infection was identified in postal workers 9 days later, the facility was closed. To determine if exposure to airborne B. anthracis spores continued to occur, we performed air sampling around the contaminated sorter. One CFU of B. anthracis was isolated from 990 L of air sampled before the machine was activated. Six CFUs were isolated during machine activation and processing of clean dummy mail. These data indicate that an employee working near this machine might inhale approximately 30 B. anthracis-containing particles during an 8-h work shift. What risk this may have represented to postal workers is not known, but the risk is approximately 20-fold less than estimates of sub-5 micron B. anthracis-containing particles routinely inhaled by asymptomatic, unvaccinated workers in a goat-hair mill.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.