Objectives:To evaluate corneal biomechanics before and after collagen crosslinking (CXL) in patients with progressive keratoconus.Materials and Methods:In this prospective study, CXL was performed under topical anesthesia after removal of the epithelium (epi-off technique) by applying ultraviolet A (UVA) light at a wavelength of 365 nm and power of 3 mW/cm2 or 5.4 joule/cm2. Isoosmolar 0.1% riboflavin solution was administered before and during UVA irradiation. In addition to ophthalmologic examination, ocular response analyzer measurements were performed pre- and postoperatively. Corneal hysteresis (CH), corneal resistance factor (CRF), corneal compensated intraocular pressure (IOPcc), Goldmann-correlated intraocular pressure (IOPg), and central corneal thickness (CCT) were recorded.Results:The study included 35 eyes of 30 patients with progressive keratoconus. The mean age was 28.2±6.5 years and postoperative follow-up time was 20.2±14.7 months (range: 6-74 months). The mean CH was 8.60±1.23 mmHg preoperatively, 8.96±2.05 mmHg in the early postoperative period (1-6 months), (p=0.28) and 8.96±1.28 mmHg in the late postoperative period (10-29 months) (p=0.48). Mean CRF was 7.13±1.50 mmHg preoperatively, 8.48±2.16 mmHg in the early postoperative period (p=0.009), and 7.71±1.29 mmHg in the late postoperative period (p=0.40). Mean IOPcc was 12.78±2.34 mmHg preoperatively, 15.38±4.21 mmHg in the early postoperative period (p=0.12) and 13.68±3.61 mmHg in the late postoperative period (p=0.48). Mean IOPg was 9.56±2.73 mmHg preoperatively, 13.01±4.45 mmHg in the early postoperative period (p=0.046), and 10.86±3.47 mmHg in the late postoperative period (p=0.44). Mean CCT was 484.43±41.26 µm preoperatively, 474.16±64.74 µm in the early postoperative period (p=0.70), and 470.38±33.64 µm in late postoperative period (p=0.71).Conclusion:CXL is a treatment modality believed to affect corneal biomechanics in keratoconus, but the results of larger patient series with longer follow-up periods may enable a better evaluation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.