In this study, the PTW 1000SRS array with Octavius 4D phantom was characterised for FF and FFF beams. MU linearity, field size, dose rate, dose per pulse (DPP) response and dynamic conformal arc treatment accuracy of the 1000SRS array were assessed for 6MV, 6FFF and 10FFF beams using a Varian TrueBeam STx linac. The measurements were compared with a pinpoint IC, microdiamond IC and EBT3 Gafchromic film. Measured dose profiles and FWHMs were compared with film measurements. Verification of FFF volumetric modulated arc therapy (VMAT) clinical plans were assessed using gamma analysis with 3%/3 mm and 2%/2 mm tolerances (10% threshold). To assess the effect of cross calibration dose rate, clinical plans with different dose rates were delivered and analysed. Output factors agreed with film measurements to within 4.5% for fields between 0.5 and 1 cm and within 2.7% for field sizes between 1.5 and 10 cm and were highly correlated with the microdiamond IC detector. Field sizes measured with the 1000SRS array were within 0.5 mm of film measurements. A drop in response of up to 1.8%, 2.4% and 5.2% for 6MV, 6FFF and 10FFF beams respectively was observed with increasing nominal dose rate. With an increase in DPP, a drop of up to 1.7%, 2.4% and 4.2% was observed in 6MV, 6FFF and 10FFF respectively. The differences in dose following dynamic conformal arc deliveries were less than 1% (all energies) from calculated. Delivered VMAT plans showed an average pass percentage of 99.5(±0.8)% and 98.4(±3.4)% with 2%/2 mm criteria for 6FFF and 10FFF respectively. A drop to 97.7(±2.2)% and 88.4(±9.6)% were observed for 6FFF and 10FFF respectively when plans were delivered at the minimum dose rate and calibrated at the maximum dose rate. Calibration using a beam with the average dose rate of the plan may be an efficient method to overcome the dose rate effects observed by the 1000SRS array.
Purpose: The aim of this study was to optimise patient dose and image quality of Varian TrueBeam cone beam computed tomography (CBCT) pelvis, thorax and head and neck (H&N) images based on patient size. Methods: An elliptical phantom of small, medium and large size was designed representative of a local population of pelvis, thorax and H&N patients. The phantom was used to establish the relationship between image noise, CT and CBCT exposure settings. Using this insight, clinical images were optimised in phases and the image quality graded qualitatively by radiographers. At each phase, the time required to match the images was recorded from the record and verify system. Results: Average patient diameter was a suitable metric to categorise patient size. Phantom measurements showed the power relationship between noise and CBCT exposure settings of value −0·15, −0·35 and −0·43 for thorax, pelvis and H&N, respectively. These quantitative phantom measurements provided confidence that phased variation of ~±20% in mAs should result in clinically usable images. Qualitative assessment of almost 2000 images reduced the exposure settings in H&N images by −50%, thorax images by up to −66% and pelvis images by up to −80%. These optimised CBCT settings did not affect the time required to match images. Findings: Varian TrueBeam CBCT mAs settings have been optimised for dose and image quality based on patient size for three treatment sites: pelvis, thorax and H&N. Quantitative phantom measurements provided insight into the magnitude of change to implement clinically. The final optimised exposure settings were determined from radiographer qualitative image assessment.
Introduction: Stereotactic radiosurgery (SRS) has proven itself as an effective tool in the treatment of intracranial lesions. Image-guided high dose single fraction treatments have the potential to deliver ablative doses to tumours; however, treatment times can be long. Flattening filter free (FFF) beams are available on most modern linacs and offer a higher dose rate compared to conventional flattened beams which should reduce treatment times. This study aimed to compare 6 MV FFF and 10 MV FFF to a 6 MV flattened beam for single fraction dynamic conformal arc SRS for a Varian Truebeam linac. Materials and methods: In total, 21 individual clinical treatment plans for 21 brain metastases treated with 6 MV were retrospectively replanned using both 6 MV FFF and 10 MV FFF. Plan quality and efficiency metrics were evaluated by analysing dose coverage, dose conformity, dose gradients, dose to normal brain, beam-on-time (BOT), treatment time and monitor units. Results: FFF resulted in a significant reduction in median BOT for both 6 MV FFF (57·9%; p < 0·001) and 10 MV FFF (76·3%; p < 0·001) which led to reductions in treatment times of 16·8 and 21·5% respectively. However, 6 MV FFF showed superior normal brain dose sparing (p < 0·001) and dose gradient (p < 0·001) compared to 10 MV FFF. No differences were observed for conformity. Conclusion: 6 MV FFF offers a significant reduction in average treatment time compared to 6 MV (3·7 minutes; p = 0·002) while maintaining plan quality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.