Aims Computer-based applications are increasingly being used by orthopaedic surgeons in their clinical practice. With the integration of technology in surgery, augmented reality (AR) may become an important tool for surgeons in the future. By superimposing a digital image on a user’s view of the physical world, this technology shows great promise in orthopaedics. The aim of this review is to investigate the current and potential uses of AR in orthopaedics. Materials and Methods A systematic review of the PubMed, MEDLINE, and Embase databases up to January 2019 using the keywords ‘orthopaedic’ OR ‘orthopedic AND augmented reality’ was performed by two independent reviewers. Results A total of 41 publications were included after screening. Applications were divided by subspecialty: spine (n = 15), trauma (n = 16), arthroplasty (n = 3), oncology (n = 3), and sports (n = 4). Out of these, 12 were clinical in nature. AR-based technologies have a wide variety of applications, including direct visualization of radiological images by overlaying them on the patient and intraoperative guidance using preoperative plans projected onto real anatomy, enabling hands-free real-time access to operating room resources, and promoting telemedicine and education. Conclusion There is an increasing interest in AR among orthopaedic surgeons. Although studies show similar or better outcomes with AR compared with traditional techniques, many challenges need to be addressed before this technology is ready for widespread use. Cite this article: Bone Joint J 2019;101-B:1479–1488
Introduction: Acute compartment syndrome (ACS) is a well-recognized and common emergency. Undiagnosed ACS leads to muscle necrosis, limb contracture, intractable pain, and may even result in amputation. Methods: Three devices (Synthes, Stryker, and MY01) were compared in a pre-clinical rat abdominal compartment syndrome simulation. Simultaneous measurements of intracompartmental pressures allowed concurrent comparison among all devices. Results: Large variations from the reference values are seen with the Synthes and Stryker devices. Variances are large in these two devices even under ideal conditions. The MY01 device was the truest indicator of reference pressure in this ACS model (over 600% more accurate). Conclusions: The MY01 device was the most accurate device in tracking pressure changes in this rat model of abdominal compartment syndrome.
Background: Anatomic anterior cruciate ligament (ACL) reconstruction improves knee kinematics and joint stability in symptomatic patients who have ACL deficiency. Despite a concerted effort to place the graft within the ACL’s native attachment sites, the accuracy of tunnel placement using contemporary techniques is not well established. Purpose: To use 3-dimensional magnetic resonance imaging (3D MRI) to prospectively evaluate the accuracy of tibial tunnel placement after anatomic ACL reconstruction. Study Design: Case series; Level of evidence, 4. Methods: Forty patients with symptomatic, ACL-deficient knees were prospectively enrolled in the study and underwent 3D MRI of both their injured and uninjured knees before and after surgery through use of a validated imaging protocol. The root ligament of the anterior horn of the lateral meniscus was used as a radiographic reference, and the center of the reconstructed graft was compared with that of the contralateral normal knee. The tunnel angles and intra-articular graft angles were also measured, as was the percentage overlap between the native tibial footprint and tibial tunnel. Results: The reconstructed tibial footprint was placed at a mean ± SD of 2.14 ± 2.45 mm ( P < .001) medial and 5.11 ± 3.57 mm ( P < .001) posterior to the native ACL footprint. The mean distance between the center of the native and reconstructed ACL at the tibial attachment site was 6.24 mm. Of the 40 patients, 18 patients had a tibial tunnel that overlapped more than 50% of the native footprint, and 10 patients had maximal (100%) overlap. Further, 22 of the 40 patients had less than 50% overlap with the native footprint, and in 12 patients the footprint was missing completely. Conclusion: Despite the use of contemporary surgical techniques to perform anatomic ACL reconstruction, a significant positioning error in tibial tunnel placement remains.
Study Design: Systematic review. Objectives: Adult spinal deformity (ASD) can be a debilitating condition with a profound impact on patients’ health-related quality of life (HRQoL). Many reports have suggested that the frailty status of a patient can have a significant impact on the outcome of the surgery. The present review aims to identify all pre-operative patient-specific frailty markers that are associated with postoperative outcomes following corrective surgery for ASD of the lumbar and thoracic spine. Methods: A systematic review of the literature was performed to identify findings regarding pre-operative markers of frailty and their association with postoperative outcomes in patients undergoing ASD surgery of the lumbar and thoracic spine. The search was performed in the following databases: PubMed, Embase, Cochrane and CINAHL. Results: An association between poorer performance on frailty scales and worse postoperative outcomes. Comorbidity indices were even more frequently employed with similar patterns of association between increased comorbidity burden and postoperative outcomes. Regarding the assessment of HRQoL, worse pre-operative ODI, SF-36, SRS-22 and NRS were shown to be predictors of post-operative complications, while ODI, SF-36 and SRS-22 were found to improve post-operatively. Conclusions: The findings of this review highlight the true breadth of the concept of “frailty” in ASD surgical correction. These parameters, which include frailty scales and various comorbidity and HRQoL indices, highlight the importance of identifying these factors preoperatively to ensure appropriate patient selection while helping to limit poor postoperative outcomes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.