Purpose: To assess reliability of diffusion-weighted magnetic resonance imaging (DW-MRI) in the management of acute pyelonephritis (APN) foci in transplanted kidneys. Materials and methods: In the 2012-2014 period, 24 kidney-transplanted patients underwent MR screening for clinical suspicion of APN. Two readers independently analyzed all images, establishing presence and location of APN foci. The 22 patients who were positive at the MR exam constituted the study population. For each patient the apparent diffusion coefficient (ADC) was measured in the APN foci and in three sites of the healthy parenchyma (case-control comparison). The data were matched to the laboratory measurements for white blood cell, C-reactive protein, and serum creatinine. Results: Forty-six APN foci were found in 22/24 patients. At the acute stage, the difference in ADC between healthy parenchyma and APN foci was significant (2.06 ± 0.16 vs. 1.43 ± 0.32 9 10 -3 mm 2 /s; p < 0.0001). The performance of ADC as APN indicator was tested by the receiving operating characteristics (ROC) curve: the area under curve AUC = 0.99 witnessed an excellent discriminatory ability, with threshold APN/normal parenchyma 1.9 9 10 -3 mm 2 /s. At the 1-month follow-up 43/46 APN foci were no longer visible, with ADC values significantly higher than at the acute stage; all laboratory data were physiological, with WBC significantly reduced from the acute phase (5.2 ± 1.6 9 10 9 /L vs. 10.6 ± 4.8 9 10 9 /L; p < 0.0001). The other 3 patients underwent further therapy and exams, including a third MR.Conclusions: DW-MRI with ADC measurement seems to be a reliable tool in diagnosing and monitoring APN foci in transplanted kidneys, with clinical impact on patient management.
BackgroundThe whole-body low-dose CT (WBLDCT) is the first-choice imaging technique in patients with suspected plasma cell disorder to assess the presence of osteolytic lesions. We investigated the performances of an optimized protocol, evaluating diagnostic accuracy and effective patient dose reduction using a latest generation scanner.Methods and MaterialsRetrospective study on 212 patients with plasma cell disorders performed on a 256-row CT scanner. First, WBLDCT examinations were performed using a reference protocol with acquisition parameters obtained from literature. A phantom study was performed for protocol optimization for subsequent exams to minimize dose while maintaining optimal diagnostic accuracy. Images were analyzed by three readers to evaluate image quality and to detect lesions. Effective doses (E) were evaluated for each patient considering the patient dimensions and the tube current modulation.ResultsA similar, very good image quality was observed for both protocols by all readers with a good agreement at repeated measures ANOVA test (p>0.05). An excellent inter-rater agreement for lesion detection was achieved obtaining high values of Fleiss’ kappa for all the districts considered (p<0.001). The optimized protocol resulted in a 56% reduction of median DLP (151) mGycm, interquartile range (IQR) 128–188 mGycm vs. 345 mGycm, IQR 302–408 mGycm), of 60% of CTDIvol (2.2 mGy, IQR 1.9–2.7 mGy vs. 0.9 mGy, IQR 0.8–1.2 mGy). The median E value was about 2.6 mSv (IQR 1.7–3.5 mSv) for standard protocol and about 1.5 mSv (IQR 1.4–1.7 mSv) for the optimized one. Dose reduction was statistically significant with p<0.001.ConclusionsProtocol optimization makes ultra-low-dose WBLDCT feasible on latest generation CT scanners for patients with plasma cell disorders with effective doses inferior to conventional skeletal survey while maintaining excellent image quality and diagnostic accuracy. Dose reduction is crucial in such patients, as they are likely to undergo multiple whole-body CT scans during follow-up.
BackgroundThe role of planned angiographic control (PAC) over a conservative management driven by symptoms and ischaemia following percutaneous coronary intervention (PCI) of the unprotected left main (ULM) with second-generation drug-eluting stents remains controversial. PAC may timely detect intrastent restenosis, but it is still unclear if this translated into improved prognosis.Methods and analysisPULSE is a prospective, multicentre, open-label, randomised controlled trial. Consecutive patients treated with PCI on ULM will be included, and after the index revascularisation patients will be randomised to PAC strategy performed with CT coronary after 6 months versus a conservative symptoms and ischaemia-driven follow-up management. Follow-up will be for at least 18 months from randomisation. Major adverse cardiovascular events at 18 months (a composite endpoint including death, cardiovascular death, myocardial infarction (MI) (excluding periprocedural MI), unstable angina, stent thrombosis) will be the primary efficacy outcome. Secondary outcomes will include any unplanned target lesion revascularisation (TLR) and TLR driven by PAC. Safety endpoints embrace worsening of renal failure and bleeding events. A sample size of 550 patients (275 per group) is required to have a 80% chance of detecting, as significant at the 5% level, a 7.5% relative reduction in the primary outcome.Trial registration numberNCT04144881
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.