Background
Glucocorticoid treatment remains the cornerstone of therapy for immune checkpoint inhibitor (ICI) myocarditis, but data supporting the use of additional immunotherapy for steroid refractory cases remains limited. We investigate the safety and efficacy of infliximab in patients with ICI myocarditis who are refractory to corticosteroids. Additionally, we highlight the importance of a multi-disciplinary approach in the care for these complex patients.
Methods
We retrospectively identified consecutive patients who developed ICI myocarditis at our institution between January 2017 and January 2020. Baseline characteristics, laboratory data and clinical outcomes were compared between patients who received infliximab and those who did not.
Results
Of a total of 11 patients who developed ICI myocarditis, 4 were treated with infliximab. Aside from age, there were no significant differences in baseline patient characteristics between the two groups including total number of ICI doses received and duration from initial ICI dose to onset of symptoms. The time to troponin normalization was 58 vs. 151.5 days (p = 0.25). The duration of prednisone taper was longer in the infliximab group (90 vs. 150 days p = 0.32). All patients survived initial hospital admission. Over a median follow-up period of 287 days, two of the 4 patients died from sepsis 2 and 3 months after initial treatment of their myocarditis; one of these patients was on a steroid taper and the other patient had just completed a steroid taper.
Conclusions
Infliximab, despite its black box warning in patients with heart failure, may be a safe and effective treatment for ICI myocarditis.
Continuous-flow left ventricular assist devices (CF-LVAD) have been shown to enhance reverse remodeling and myocardial recovery in certain patients allowing for device removal. We sought to analyze the characteristics and describe outcomes of patients who underwent CF-LVAD explantation at a large academic center. We retrospectively identified all patients who underwent CF-LVAD explants due to recovery from 2006 to 2019. Patient baseline characteristics and data on pre- and postexplant evaluation were collected and analyzed. Of 421 patients who underwent CF-LVAD implantation, 13 underwent explantation (3.1%). Twelve HeartMate II and one HeartWare LVAD were explanted. All patients had nonischemic cardiomyopathy. Median time from heart failure diagnosis to LVAD implant was 12 months (interquartile range [IQR], 2–44) and the median time supported on LVAD was 22 months (IQR, 11–28). Two patients died within 30 days of explant. Three additional patients died during the follow-up period and all were noted to be nonadherent to medical therapy. After a mean follow-up duration of 5 years, overall survival was 52%. Mean pre-explant ejection fraction was 49%, which decreased at most recent follow-up to 32%. Mean pre-explant left ventricular internal diameter in diastole (LVIDD) was 4.37 cm and increased to 5.52 cm at most recent follow-up. Continuous-flow left ventricular assist device explantation is feasible and safe in select patients.
We aimed to identify a simple metric accounting for peri-procedural hemoglobin changes, independent of blood product transfusion strategies, and assess its correlation with outcomes in patients undergoing left ventricular assist device (LVAD) implantation We included consecutive patients undergoing LVAD implantation at a single center between 10/1/2008 and 6/1/2014. The anemia stress index (ASI), defined as the sum of number of packed red blood cells transfused and the hemoglobin changes after LVAD implantation, was calculated for each patient at 24 h, discharge, and 3 months after LVAD implantation. Our cohort included 166 patients (80.1% males, mean age 56.3 ± 15.6 years) followed up for a median of 12.3 months. Increases in ASI per unit were associated with a higher hazard for all-cause mortality and early RV failure. The associations between the ASI and all-cause mortality persisted after multivariable adjustment, irrespective of when it was calculated (adjusted HR of 1.11, 95% CI 1.03–1.20 per unit increase in ASI). Similarly, ASI at 24 h after implant was associated with early RV failure despite multivariable adjustment (OR 1.09, 95% CI 1.05–1.14). We present a novel metric, the ASI, that is correlated with an increased risk for all-cause mortality and early RV failure in LVAD recipients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.