Background: The impact of anterior cruciate ligament reconstruction (ACLR) on the performance and career of professional soccer players has not been extensively investigated. Purpose: To evaluate in professional European soccer players (1) the ACL injury incidence, (2) the return-to-play (RTP) rate and time after ACLR, (3) career survival and athlete performance in the first 3 postoperative seasons after RTP, (4) factors likely related to different outcomes after ACLR, and (5) any related differences between the top 8 European soccer leagues. Study Design: Descriptive epidemiology study. Methods: Included were professional soccer players in the top 8 European Soccer leagues (Serie A [Italy], Premier League [England], Ligue 1 [France], LaLiga [Spain], Bundesliga [Germany], Jupiler Pro League [Belgium], Liga NOS [Portugal], and Premier Liga [Russia]) who sustained an ACL injury during seasons 2014 to 2015, 2015 to 2016, and 2016 to 2017. Data were retrieved from publicly available online sources. Outcomes were evaluated based on player age (<25 years, 25-30 years, and >30 years), position (goalkeeper, defender, midfielder, and forward), affected side (dominant vs nondominant), and league. Results: Overall, 195 players sustained an ACL injury, for a mean annual ACL injury incidence of 1.42%. The RTP rate was 95%, with a mean RTP time of 248 ± 136 days. Within the third postoperative season, 66 players (36%) competed in a lower level national league, and 25 (13.6%) ended their careers; a significant reduction in the mean minutes played per season was found in all 3 postoperative seasons. Player age correlated significantly with reduction in performance or recovery from an ACL injury. No significant correlation was found between postoperative player performance and affected side, position, league, or time to RTP. Conclusion: A substantial ACL injury incidence was found in top European elite soccer players; however, a high RTP rate in a reasonable time was seen after ACLR. Nevertheless, professional soccer players experienced a short-term decline in their performance.
Purpose: Treatment of patients with dementia and hip fracture is challenging. Total hip arthroplasty (THA) with dual mobility cup (DMC) has been designed to reduce the rate of dislocation by increasing the stability of the implant. This study aimed to compare the dislocation rates of DMC THA with hemiarthroplasty (HA) in elderly patients with displaced femoral neck fracture (FNF) and a diagnosis of dementia. Methods: All patients with a displaced FNF and dementia diagnosis were prospectively randomized to hemiarthroplasty or THA with DMC treatment during a 2-year period. Finally, the outcomes of 30 patients in the HA group were compared with those of 30 patients in the DMC THA group. Dislocation rate at a minimum follow-up of 1 year was evaluated as the primary outcome. Reoperation rate, time to surgery, surgical time, length of hospital stay, and 30-day and 1-year mortality were also evaluated. Results: There was a significant difference regarding rates of dislocation in favor of THA with DMC and with regard to length of surgery (p = 0.04) in favor of bipolar HA. Dislocation occurred in five patients (16.6%) treated with bipolar HA and no one (0%) in patients treated with THA with DMC (p = 0.019). There was no difference with regard to the 30-day mortality, 1-year mortality, reoperations, and length of hospital stay between the two groups of patients. Discussion: THA with DMC seems to be a safe and reliable choice to reduce the rate of dislocation at 1 year in patients with dementia and FNF without a higher risk of mortality.
Purpose The purpose of this study was to determine the most reliable radiographic measurement method to evaluate PTS as a risk factor for ACL reconstruction failure. Methods Patients who underwent ACL reconstruction or ACL revision reconstruction between January 2009 and December 2014 by a single surgeon were included. Fifty-two consecutive patients who underwent ACL revision reconstruction were compared to a random selection of 52 patients who underwent primary ACL reconstruction and a control group of 52 patients without ACL injury. ACL reconstruction was performed using either ipsilateral (primary) or contralateral (revision) quadrupled hamstring autograft. Lateral knee radiographs were evaluated using three methods: (1) longitudinal axis, (2) anterior tibial cortex axis, and (3) posterior tibial cortex. Results A significant difference was found between subjects who underwent ACL reconstruction and control knees (6.79°vs. 5.31°, p = 0.046) using the posterior tibial cortex method. No other statistical significance was found between groups. A multiple linear regression analysis found that the PTS as measured by any method was not affected by the patient's age, sex, height, weight, and BMI. All methods of measurement for PTS demonstrated excellent (ICC > 0.90) intra-rater and inter-rater reliability, but only the posterior tibial cortex method maintained excellent intra-rater and inter-rater reliability (ICC > 0.90) when evaluating patients with ACL revision reconstruction. Conclusions The posterior tibial cortex measurement is the most reliable method for analyzing the PTS on lateral knee radiographs in patients undergoing ACL revision reconstruction.
The functional positioning of components in a total hip arthroplasty (THA) and its relationship with individual lumbopelvic kinematics and a patient’s anatomy are being extensively studied. Patient-specific kinematic planning could be a game-changer; however, it should be accurately delivered intraoperatively. The main purpose of this study was to verify the reliability and accuracy of a patient-specific instrumentation (PSI) and laser-guided technique to replicate preoperative dynamic planning. Thirty-six patients were prospectively enrolled and received dynamic hip preoperative planning based on three functional lateral spinopelvic X-rays and a low dose CT scan. Three-dimensional (3D) printed PSI guides and laser-guided instrumentation were used intraoperatively. The orientation of the components, osteotomy level and change in hip length and offset were measured on postoperative CT scans and compared with the planned preoperative values. The length of surgery was compared with that of a matched group of thirty-six patients who underwent a conventional THA. The mean absolute deviation from the planned inclination and anteversion was 3.9° and 4.4°, respectively. In 92% of cases, both the inclination and anteversion were within +/− 10° of the planned values. Regarding the osteotomy level, offset change and limb length change, the mean deviation was, respectively, 1.6 mm, 2.6 mm and 2 mm. No statistically significant difference was detected when comparing the planned values with the achieved values. The mean surgical time was 71.4 min in the PSI group and 60.4 min in the conventional THA group (p < 0.05). Patient-specific and laser-guided instrumentation is safe and accurately reproduces dynamic planning in terms of the orientation of the components, osteotomy level, leg length and offset. Moreover, the increase in surgical time is negligible.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.