ObjectiveThe aim of this study was to investigate whether aortic tension estimated by palpation and cardioplegia infusion line pressure provide results equivalent to those obtained with direct aortic intraluminal pressure measurement.MethodsSixty consecutive patients who underwent coronary artery bypass graft surgeries with extracorporeal circulation were analyzed. Sanguineous cardioplegic solution in a ratio of 4:1 was administered using a triple lumen antegrade cannula. After crossclamping, cardioplegia was infused and aortic root pressure was recorded by surgeon (A) considering the aortic tension he felt in his fingertips. At the same time, another surgeon (B) recorded his results for the same measurement. Concomitantly, the anesthesiologist recorded intraluminal pressure in the aortic root and the perfusionist recorded delta pressure in cardioplegia infusion line. None of the participants involved in these measurements was allowed to be informed about the values provided by the other examiners.ResultsThe Bland-Altman test showed that a considerable variation between aortic wall tension was found as measured by palpation and by intraluminal pressure, with a bias of -9.911±18.75% (95% limits of agreement: -46.7 to 26.9). No strong correlation was observed between intraluminal pressure and cardioplegia line pressure (Spearman's r=0.61, 95% confidence interval 0.5-0.7; P<0.0001).ConclusionThese findings reinforce that cardioplegia infusion should be controlled by measuring intraluminal pressure, and that palpation and cardioplegia line pressure are inaccurate methods, the latter should always be used to complement intraluminal measurement to ensure greater safety in handling the cardioplegia circuit.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.