We report our experience using transradial access (TRA) for carotid artery stenting (CAS). Eighty-eight patients underwent CAS using a nonfemoral approach, 79 of them by TRA. Carotid artery stenting was performed using standard techniques with a long hydrophilic sheath. Mean age was 69.5 years. A total of 46 patients were symptomatic and 34 were asymptomatic. Transradial access and procedural success were achieved in 98.8% and 96.6% of the cases, respectively. There were no deaths, myocardial infarction, or radial access site complications. In all, 2 patients sustained a stroke, 1 hemorrhage, and 1 ischemia. Carotid artery stenting using TRA was safe and technically feasible.
Background and Aim. Conduction disturbances leading to permanent pacemaker implantation (PPMI) remains a common complication for TAVR procedures, particularly when self-expanding valves are used. We compared the 30-day incidence of new-onset left bundle branch block (LBBB) and permanent pacemaker implantation (PPMI) rate between two consecutive groups using either conventional 3-cusp coplanar view (CON) and right/left cusp-overlap view (COVL) for implantation. Methods and Results. We retrospectively compared 257 consecutive patients undergoing TAVR with self-expandable valves using either CON (n = 101) or COVL (n = 156) in four intermediate/low volume centers. There were no significant differences in baseline characteristics between the groups. The 30-day incidence of new-onset LBBB (12.9% vs. 5.8%;
p
=
0.05
) and PPMI rate (17.8% vs. 6.4%;
p
=
0.004
) was significantly lower when using the COVL implantation view. There was no difference between the CON and COVL groups in 30-day incidence of death (4.9% vs. 2.6%), any stroke (0% vs. 0.6%), and the need for surgical aortic valve replacement (0% for both groups). Conclusion. Using the COVL view for implantation, we achieved a significant reduction of the LBBB and PPMI rate after TAVR in comparison with the traditional CON view, without compromising the TAVR outcomes when using self-expandable prostheses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.