Abstract -Four-wire microgrids and distribution systems are inherently unbalanced with the presence of negative and zero sequence components in voltages and currents. In small autonomous systems the imbalance, in addition to the harmonic distortion produced by non-linear loads, can significantly affect power quality, loadability and stability of the system. Furthermore, in isolated networks with significant generation from intermittent renewable energy sources, the stiffness of the system is reduced and this could amplify the effects of imbalance on the stability and power quality. To mitigate some of these problems, a novel methodology based on the application of a 4-leg Active Power Filter (APF) is proposed in this paper. The control of the compensator is based on the Conservative Power Theory (CPT) augmented by Resonant Controllers. The behaviour of the proposed system is demonstrated using an experimental prototype deployed in a laboratory scale microgrid Index Terms-Active power filter, conservative power theory, resonant control, microgrids, imbalance, harmonic distortion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.