Over the last few years, portable Near-Infrared Spectroscopy (NIRS) technology has been suggested for determining metabolic/ventilator thresholds. This systematic review and meta-analysis aimed to assess the reliability of a portable muscle oxygenation monitor for determining thresholds during exercise testing. The proposed PICO question was: Is the exercise intensity of muscle oxygenation thresholds, using portable NIRS, reliable compared with lactate and ventilatory thresholds for exercise intensity determined in athletes? A search of Pubmed, Scopus and Web of Science was undertaken and the review was conducted following PRISMA guidelines. Fifteen articles were included. The domains which presented the highest biases were confounders (93% with moderate or high risk) and participant selection (100% with moderate or high risk). The intra-class correlation coefficient between exercise intensity of the first ventilatory or lactate threshold and the first muscle oxygenation threshold was 0.53 (obtained with data from only 3 studies), whereas the second threshold was 0.80. The present work shows that although a portable muscle oxygenation monitor has moderate to good reliability for determining the second ventilatory and lactate thresholds, further research is necessary to investigate the mathematical methods of detection, the capacity to detect the first threshold, the detection in multiple regions, and the effect of sex, performance level and adipose tissue in determining thresholds.
The response of female cyclists depending on the functional test duration has not been studied. This study aims to analyse the effect of modification of the duration of two different functional tests: Wingate (WAnT) and Functional Power Threshold (FTP) in female cyclists. Fourteen cyclists (27 ±8 years, 1.66 ±0.08 m, and 60.6 ±7.2 kg) performed 2 test days with a 24-hour break between days, varying the test duration (WAnT 20- or 30-sec, and FTP 8- or 10-min). Relative power output, cadence, heart rate, local oxygen saturation, lactate, and rating of perceived exertion were measured in each test. Time duration did not affect the power output outcomes in both tests (p>0.05). However, WAnT of 20 sec, compared with the test of 30 sec, resulted in a lower cadence decrease in the last 5 sec (p<0.01, ES=1.3), lower heart rate variables (peak, average and variation; p<0.01, ES>0.5), and higher execution inclination of local oxygen saturation (p<0.05 and ES=1.0). In conclusion, the time variations assessed do not alters power outcomes in female cyclists. However, higher acute fatigue can be observed in the WAnT of 30 sec, which suggests the use of the test of 20 sec to allow continue training afterwards.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.