The Romanian standard for the analytical method for phenols measurements in aquatic media was subject of internal validation procedure, adapted to the specific concentration domain of the laboratory. Method performance criteria were investigated on standard samples measurements: selectivity, linearity domain, precision, accuracy, limit of detection, limit of quantification and robustness. The validated method was further used on real samples of domestic and industrial wastewaters from the Wastewater Treatment Plant of Brasov, Romania. As a novelty, even not required in the Romanian standard, sources of uncertainties were identified, and uncertainty was estimated for both measurements on standard and wastewater samples. The results showed that the method is suitable for phenolic compounds determination from wastewaters, with a very low uncertainty level.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.