Serum thyroglobulin (Tg) measurement is a major means of detecting thyroid cancer recurrence. Unlike anti-Tg autoantibody interferences, heterophile antibody (HAB) immunoassay interferences are not well recognized by laboratorians or clinicians as a Tg assay problem. When HAB interferences occur, they usually result in false positive test results. With the current trend to treat some thyroid cancer patients with radioiodine on the basis of an elevated serum Tg result alone, this has the potential to result in unwarranted therapy. We evaluated the prevalence of HAB interference in a commonly used automated immunoassay in 1106 consecutive specimens with Tg values greater than 1 ng/ml. All Tg measurements were repeated after sample incubation in heterophile-blocking tubes (HBT). Results, which showed a more than 3 SD percentage difference from the original result, were considered to suffer from HAB interference. All possible interferences were confirmed by dilution testing. After HBT treatment, Tg levels dropped to less than 1 ng/ml in 32 specimens (P < 0.0000001), 20 of which fell to less than 0.1 ng/ml (P < 0.00002). Of these 20, 17 were anti-Tg autoantibody negative, and all 32 showed a fall of greater than 3 SD percentage (>56.91%) compared with the original result. There were also two samples that showed a significant increase of greater than 56.91% after HBT treatment. HAB interference is relatively prevalent (1.5-3%) in a commonly used automated Tg assay and can lead to clinically significant artifacts. It is currently unknown, but possible, that other immunometric Tg assays suffer from similar problems. Unless a Tg assay is confirmed to be free of HAB interference or uses additional blocking steps, as ours now does, HAB interference should be suspected if Tg results do not fit the clinical picture.
A strong correlation was observed between PCT and CT levels in patients with MCT. Given PCT's greater analytical stability, we conclude that it represents a promising complementary MTC tumor marker.
Unless plasma fractionated metanephrines levels are elevated more than 4-fold above the upper limit of normal, patients with a positive plasma fractionated metanephrines test should be evaluated with urine fractionated metanephrines and serum/plasma CGA assays before being subjected to imaging or invasive diagnostic tests.
CSF 14-3-3 and neuron-specific enolase (NSE) proteins were quantitated from patients who had Creutzfeldt-Jakob disease (CJD) or other rapidly dementing disorders initially considered to be CJD. Thirty-one patients were diagnosed as having CJD among 152 studied. CSF 14-3-3 values more than 8 ng/mL correlated with CJD. CSF NSE values less than 30 ng/mL and 14-3-3 values less than 8 ng/mL made a diagnosis of CJD unlikely, but did not exclude it.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.