ObjectiveMultiple guidelines recommend continuing hydroxychloroquine (HCQ) for SLE during pregnancy based on observational data. The goal of this individual patient data meta-analysis was to identify the potential benefits and harms of HCQ use within lupus pregnancies.MethodsEligible studies included prospectively collected pregnancies in women with lupus. After a systematic literature search, seven datasets meeting inclusion criteria were obtained. Pregnancy outcomes and lupus activity were compared for pregnancies with a visit in the first trimester in women who did or did not take HCQ throughout pregnancy. Birth defects were not systematically collected. This analysis was conducted in each dataset, and results were aggregated to provide a pooled OR.ResultsSeven cohorts provided 938 pregnancies in 804 women. After selecting one pregnancy per patient with a first trimester visit, 668 pregnancies were included; 63% took HCQ throughout pregnancy. Compared with pregnancies without HCQ, those with HCQ had lower odds of highly active lupus, but did not have different odds of fetal loss, preterm delivery or pre-eclampsia. Among women with low lupus activity, HCQ reduced the odds of preterm delivery.ConclusionsThis large study of prospectively-collected lupus pregnancies demonstrates a decrease in lupus activity among woman who continue HCQ through pregnancy and no harm to pregnancy outcomes. Like all studies of HCQ in lupus pregnancy, this study is confounded by indication and non-adherence. As this study confirms the safety of HCQ and diminished SLE activity with use, it is consistent with current recommendations to continue HCQ throughout pregnancy.
Chronic and acute wounds, such as diabetic foot ulcers and burns, respectively, can be difficult to treat, especially when autologous skin transplantations are unavailable. Skin substitutes can be used as a treatment alternative by providing the structural elements and growth factors necessary for reepithelialization and revascularization from a nonautologous source. As of 2020, there are 76 commercially available skin substitute products; this article provides a review of the relevant literature related to the major categories of skin substitutes available.
Background: Refinement of the nasal tip plays an important role in rhinoplasty surgery outcomes and may be considered the most technically challenging aspect of the procedure. Numerous techniques have been described for nasal tip augmentation utilizing grafts. The aim of this study was to systematically review the existing literature on nasal tip grafts and appraise it critically. Methods: A PubMed search was performed to identify journal articles related to nasal tip grafts from the past decade. A total of 44 studies met inclusion criteria. The Newcastle-Ottawa Quality Assessment Scale and Jadad scale were used to appraise 38 observational studies and six randomized trials, respectively, to determine the quality of the studies. Results: Critical assessment revealed that the studies were highly variable in focus and encompassed autologous, homologous, and alloplastic grafts. The quality of the data included an average Newcastle-Ottawa Quality Assessment Scale score of 6.5 (out of 9) and Jadad score of 2.5 (out of 5). A majority of studies (86.4%) included objective outcomes using anthropometric measurements and a portion of studies (27.3%) also included patient-reported outcomes. Conclusions: The results of this systematic review suggest that more than one type of nasal tip graft may result in satisfactory outcomes. This review provides an expansive collection of studies on nasal tip grafts, which can serve as an invaluable tool for the plastic surgeon engaging in rhinoplasty.
The use of robotic surgical systems to perform abdominoperineal resection (APR) has recently become more prevalent. This minimally invasive approach produces fewer scars and potentially less morbidity for the patient. The rectus abdominis muscle is often used for reconstruction after APR if primary closure is not feasible or the surgical site is at high risk of wound complications. Since the traditional open harvest of this flap creates large incisions that negate the advantages of minimally invasive APR, there has been growing interest in harvesting the rectus abdominis in a similarly robotic fashion. This article reviews the technique, benefits, and limitations of this robotic technique. Compared to the traditional open harvest, robotic harvest of the rectus abdominis leaves smaller scars, provides technical benefits for the surgeon, and offers possible morbidity benefits for the patient. These advantages should be weighed against the added expense and learning curve inherent to robotic surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.