Some COVID-19 survivors suffer from persistent pulmonary function impairment, but the extent and associated factors are unclear. This study aimed to characterize pulmonary function impairment three to five months after hospital discharge and the association with disease severity. Survivors of COVID-19 after hospitalization to the VieCuri Medical Centre between February and December 2020 were invited for follow-up, three to five months after discharge. Dynamic and static lung volumes, respiratory muscle strength and diffusion capacity were measured. The cohort comprised 257 patients after a moderate (n = 33), severe (n = 151) or critical (n = 73) COVID-19 infection with a median follow-up of 112 days (interquartile range 96–134 days). The main sequelae included reduced diffusion capacity (36%) and reduced maximal expiratory pressure (24%). Critically ill patients were more likely to have reduced diffusion capacity than moderate (OR 8.00, 95% CI 2.46–26.01) and severe cases (OR 3.74, 95% CI 1.88–7.44) and lower forced vital capacity (OR 3.29, 95% CI 1.20–9.06) compared to severe cases. Many COVID-19 survivors, especially after a critical disease course, showed pulmonary function sequelae, mainly DLCO impairments, three to five months after discharge. Monitoring is needed to investigate the persistence of these symptoms and the longer-term implications of the COVID-19 burden.
BackgroundConventional radiographs and clinical reassessment are considered guides in managing clinically suspected scaphoid fractures. This is a unique study as it assessed the value of conventional radiographs and clinical reassessment in a cohort of patients, all of whom underwent additional imaging, regardless of the outcome of conventional radiographs and clinical reassessment.Questions/purposes(1) What is the diagnostic performance of conventional radiographs in patients with a clinically suspected scaphoid fracture compared with high-resolution peripheral quantitative CT (HR-pQCT)? (2) What is the diagnostic performance of clinical reassessment in patients with a clinically suspected scaphoid fracture compared with HR-pQCT? (3) What is the diagnostic performance of conventional radiographs and clinical reassessment combined compared with HR-pQCT?MethodsBetween December 2017 and October 2018, 162 patients with a clinically suspected scaphoid fracture presented to the emergency department (ED). Forty-six patients were excluded and another 25 were not willing or able to participate, which resulted in 91 included patients. All patients underwent conventional radiography in the ED and clinical reassessment 7 to 14 days later, together with CT and HR-pQCT. The diagnostic performance characteristics and accuracy of conventional radiographs and clinical reassessment were compared with those of HR-pQCT for the diagnosis of fractures since this was proven to be superior to CT scaphoid fracture detection. The cohort included 45 men and 46 women with a median (IQR) age of 52 years (29 to 67). Twenty-four patients with a median age of 44 years (35 to 65) were diagnosed with a scaphoid fracture on HR-pQCT.ResultsWhen compared with HR-pQCT, conventional radiographs alone had a sensitivity of 67% (95% CI 45% to 84%), specificity of 85% (95% CI 74% to 93%), positive predictive value (PPV) of 62% (95% CI 46% to 75%), negative predictive value (NPV) of 88% (95% CI 80% to 93%), and a positive and negative likelihood ratio (LR) of 4.5 (95% CI 2.4 to 8.5) and 0.4 (95% CI 0.2 to 0.7), respectively. Compared with HR-pQCT, clinical reassessment alone resulted in a sensitivity of 58% (95% CI 37% to 78%), specificity of 42% (95% CI 30% to 54%), PPV of 26% (95% CI 19% to 35%), NPV of 74% (95% CI 62% to 83%), as well as a positive and negative LR of 1.0 (95% CI 0.7 to 1.5) and 1.0 (95% CI 0.6 to 1.7), respectively. Combining clinical examination with conventional radiography produced a sensitivity of 50% (95% CI 29% to 71%), specificity of 91% (95% CI 82% to 97%), PPV of 67% (95% CI 46% to 83%), NPV of 84% (95% CI 77% to 88%), as well as a positive and negative LR of 5.6 (95% CI 2.4 to 13.2) and 0.6 (95% CI 0.4 to 0.8), respectively.ConclusionThe accuracy of conventional radiographs (80% compared with HR-pQCT) and clinical reassessment (46% compared with HR-pQCT) indicate that the value of clinical reassessment is limited in diagnosing scaphoid fractures and cannot be considered directive in managing scaphoid fractures. The com...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.