BackgroundPatients with methicillin-resistant S. aureus (MRSA) are thought to incur additional costs for hospitals due to longer stay and contact isolation. The aim of this study was to assess the costs associated with MRSA in Norwegian hospitals.MethodsAnalyses were based on data fromSouth-Eastern Norway for the year 2012 as registered in the Norwegian Surveillance System for Communicable Diseases and the Norwegian Patient Registry. We used a matched case-control method to compare MRSA diagnosed inpatients with non-MRSA inpatients in terms of length of stay, readmissions within 30 days from discharge, as well as the Diagnosis-Related Group (DRG) based costs.ResultsNorwegian patients with MRSA stayed on average 8 days longer in hospital than controls, corresponding to a ratio of mean duration of 2.08 (CI 95%, 1.75–2.47) times longer.A total of 14% of MRSA positive inpatients were readmitted compared to 10% among controls. However, the risk of readmission was not significantly higher for patients with MRSA. DRG based hospital costs were 0.37 (95% CI, 0.19–0.54) times higher among cases than controls, with a mean cost of EUR13,233(SD 26,899) and EUR7198(SD 18,159) respectively.ConclusionThe results of this study indicate that Norwegian patients with MRSA have longer hospital stays, and higher costs than those without MRSA.
This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
Introduction: Transvenous implantable cardioverter-defibrillators (TV-ICD) infection is a serious complication that frequently requires complete device removal for attempted cure, which can be associated with patient morbidity and mortality. The objective of this study is to assess mortality risk associated with TV-ICD infection in a large Medicare population with de novo TV-ICD implants.Methods: A survival analysis was conducted using 100% fee-for-service Medicare facility-level claims data to identify patients who underwent de novo TV-ICD
Background: Cardiac implantable electronic device transvenous (TV) lead reoperations are projected to increase, and robust economic data are needed to assess the resulting financial impact and the cost-effectiveness of prevention and treatment strategies. This study estimates Medicare costs, and describes patterns of complications, in patients who underwent TV lead reoperation. Methods and Results: Medicare data (2010-2014) were used to identify patients who underwent TV lead reoperation. Cumulative costs to Medicare, and rates of infection and mechanical complications were calculated from 180 days before, to 180 days after, lead reoperation. Multivariate analysis was used to estimate adjusted costs, and to examine the impact of complications on medical resource use and costs. There were 1691 patients, 63.2% of whom underwent inpatient lead reoperation. Overall, the mean age was 78.2 years, 39.6% were female, and 92.3% were white. The mean cumulative cost was $36 199 (95% confidence interval [CI], $31 864-$40 535) for TV lead repositioning, $27 701 (95% CI, $19 869-$35 534) for repair, and $54 442 (95% CI, $51 651-$57 233) for removal. Underlying infection was associated with increased odds of inpatient reoperation and of lead removal, as well as longer length of stay and higher costs. Conclusions: The economic consequences of TV lead reoperation are substantial. Strategies aimed at reducing reoperation, particularly lead removal, are likely to result in considerable cost offsets. K E Y W O R D S cardiac implantable electronic device, cost, reoperation, transvenous leads
Introduction: Practice guidelines recommend use of subcutaneous implantable cardioverter-defibrillators (ICD) in patients (pts) at risk of sudden cardiac death and high risk for infection. This has prompted a need to better identify pts at high risk of infection to assist in de novo device selection. The objective of this study is to estimate infection incidence in de novo transvenous (TV) ICD implants and assess risk factors associated with infection in a large Medicare population. Methods: A retrospective cohort study was conducted using 100% Medicare administrative and claims data to identify pts who underwent de novo TV-ICD implantation between 7/2016 and 1/2018. Device-related infection within 2 years of implantation was identified using ICD-10 diagnosis and procedure codes. Baseline pt factors associated with infection were identified by univariable logistic regression analysis of all variables of interest, including factors in Charlson and Elixhauser comorbidity indices, followed by stepwise selection criteria with a p≤0.25 for inclusion in a multivariable model and a backwards, stepwise elimination process with p≤0.1 to remain in the model. A time-to-event analysis was also conducted. Results: Among 26,742 pts with de novo TV-ICD, 519 (1.9%) had a device-related infection over 2 years. The mean pt age with and without infection was 68 and 71 years, respectively. While more than half (54%) of infections occurred within 90 days post implant, infections continued to be diagnosed with 16% of infections occurring between years 1 and 2. Multivariable analysis revealed several significant predictors of infection (Figure) including age <70 years, end stage renal disease with chronic dialysis and diabetes with complications. Conclusion: The rate of de novo TV-ICD infection in a large real-world Medicare population is clinically significant. The factors associated with increased infection risk identified here can be used to help determine device selection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.