Venous blood is a preferred matrix for the determination of total mercury (Hg) in human biomonitoring but has some drawbacks such as the requirement for an uninterrupted cold chain for transport and storage and the need of medical personnel for sample collection. Therefore, we tested and implemented a simpler and less expensive method for measuring Hg in human blood using dried blood spots (DBS). For method development, we investigated the influence of different storage conditions (temperature, storage vessel, time) on DBS samples. For method validation, we compared DBS and venous blood and investigated whether DBS sampling is suitable for measuring Hg in the general population in countries with low Hg exposure such as Germany. Based on our results, we found that pre-cleaned glass tubes were most suitable for storage of DBS samples, as this allowed the samples to remain stable for at least 4 weeks even at high temperatures (40 °C). When comparing venous blood and DBS, a very good correlation (r = 0.95, p < 0.01, Spearman-Rho) and high precision of DBS (mean relative standard deviation 8.2% vs. 7.2% in venous blood samples) were observed. Comparing the recoveries of both matrices in different concentration ranges, the variation of the recoveries decreases with increasing Hg concentration. The mean recoveries also decreased with increasing Hg concentration. Overall, we found comparable results for DBS and venous blood using direct Hg analysis. Furthermore, we demonstrated that DBS are suitable for Hg biomonitoring in the general population in Germany and improved the storage conditions for the DBS.
3-D printers are widely used. Based on previous findings, we hypothesized that their emissions could enhance allergen responsiveness and reduce lung diffusing capacity.Using a cross-over design, 28 young subjects with seasonal allergic rhinitis were exposed to 3-D printer emissions, either from polylactic acid (PLA) or from acrylonitrile butadiene styrene copolymer (ABS), for 2 h each. Ninety minutes later, nasal allergen challenges were performed, with secretions sampled after 1.5 h. Besides nasal functional and inflammatory responses, assessments included diffusing capacity. There was also an inclusion day without exposure. The exposures elicited slight reductions in lung diffusing capacity for inhaled nitric oxide (DL NO ) that were similar for PLA and ABS. Rhinomanometry showed the same allergen responses after both exposures.In nasal secretions, concentrations of interleukin 6 and tumor necrosis factor were slightly reduced after ABS exposure versus inclusion day, while that of interleukin 5 was slightly increased after PLA exposure versus inclusion.
Mercury (Hg) is a global pollutant and a danger to human health. Human biomonitoring of Hg using a dried blood matrix instead of venous blood sampling for exposure assessment is of growing interest. This study aims to develop, validate, and evaluate the application of volumetric absorptive microsampling (VAMS) for Hg biomonitoring in humans. Sampling, drying, and storage conditions were evaluated during method development. Storage in pre-cleaned glass vials after drying for 2 h in a desiccator ensured analyte stability for at least 4 weeks. Sixty-eight paired capillary VAMS and venous blood samples from volunteers in Munich, Germany, were used for method validation. Hg levels in VAMS and venous blood samples were determined by direct mercury analysis. The limits of detection and quantitation for VAMS were 0.18 and 0.61 µg/l, respectively. However, sensitivity could be improved by using two microsamples for analysis instead of one. Hg levels in VAMS samples correlated very well with Hg levels in venous blood samples (R2 = 0.958). Furthermore, VAMS showed a high accuracy (median recovery: 117%) and precision (median relative standard deviation: 8.7%), especially for Hg concentrations above 1.0 µg/l. In fact, accuracy and precision of VAMS improved with increasing Hg concentrations. In conclusion, VAMS in combination with direct mercury analysis is an accurate and viable alternative for human biomonitoring of Hg. Graphical abstract
Objective Despite the increasing scholarly interest in the phenomenon technostress, associated biological effects on employee health are under-researched. Chronic low-grade inflammation is suggested as a central pathway linking stress experience to disease development. The aim of this study was to assess associations of technology-related work stressors (technostressors) with low-grade inflammation and burnout symptoms. Methods N = 173 (74.6% women, Mage = 31.0 years) university hospital employees participated in a cross-sectional study. Self-report questionnaires were used for the assessment of general psychosocial working conditions (work overload, job control, social climate), a range of different technostressors, burnout symptoms, and relevant confounders. Participants provided capillary blood samples, and high-sensitivity C-reactive protein (hs-CRP) as an inflammatory biomarker was analyzed from dried blood spots. Results Based on a factor analysis, we identified four underlying dimensions of technostressors: techno- and information overload, techno-complexity, interruptions and multitasking as well as usability and technical support. In multivariate linear regressions, techno-/information overload and techno-complexity were associated with core (exhaustion, mental distance) and secondary (psychosomatic complaints) symptoms of burnout. Techno-/information overload was a significant predictor of burnout core symptoms, even when general work overload was controlled for. The technostressors were not associated with hs-CRP. Conclusion This is the first study on technology-related stress at work and chronic low-grade inflammation. The results suggest that (information) overload caused by digital technology use is a distinct work stressor with genuine consequences for psychological health. To what extent these effects also manifest on a physiological level needs to be subjected to future studies, ideally with prospective designs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.