Background Peripheral intravenous catheters (PIVCs) are ubiquitous medical devices, crucial to providing essential fluids and drugs. However, post-insertion PIVC failure occurs frequently, likely due to inconsistent maintenance practice such as flushing. The aim of this implementation study was to evaluate the impact a multifaceted intervention centred on short PIVC maintenance had on patient outcomes. Methods This single-centre, incomplete, stepped wedge, cluster randomised trial with an implementation period was undertaken at a quaternary hospital in Queensland, Australia. Eligible patients were from general medical and surgical wards, aged ≥ 18 years, and requiring a PIVC for > 24 h. Wards were the unit of randomisation and allocation was concealed until the time of crossover to the implementation phase. Patients, clinicians, and researchers were not masked but infections were adjudicated by a physician masked to allocation. Practice during the control period was standard care (variable practice with manually prepared flushes of 0.9% sodium chloride). The intervention group received education reinforcing practice guidelines (including administration with manufacturer-prepared pre-filled flush syringes). The primary outcome was all-cause PIVC failure (as a composite of occlusion, infiltration, dislodgement, phlebitis, and primary bloodstream or local infection). Analysis was by intention-to-treat. Results Between July 2016 and February 2017, 619 patients from 9 clusters (wards) were enrolled (control n = 306, intervention n = 313), with 617 patients comprising the intention-to-treat population. PIVC failure was 91 (30%) in the control and 69 (22%) in the intervention group (risk difference − 8%, 95% CI − 14 to − 1, p = 0.032). Total costs were lower in the intervention group. No serious adverse events related to study intervention occurred. Conclusions This study demonstrated the effectiveness of post-insertion PIVC flushing according to recommended guidelines. Evidence-based education, surveillance and products for post-insertion PIVC management are vital to improve patient outcomes. Trial registration Trial submitted for registration on 25 January 2016. Approved and retrospectively registered on 4 August 2016. Ref: ACTRN12616001035415.
Background: Peripheral intravenous catheters (PIVCs) are the most commonly used invasive medical device, yet despite best efforts by end-users, PIVCs experience unacceptably high early failure rates. We aimed to design a new PIVC that reduces the early failure rate of in-dwelling PIVCs and we conducted preliminary tests to assess its efficacy and safety in a large animal model of intravenous access. Methods: We used computer-aided design and simulation to create a PIVC with a ramped tip geometry, which directs the infused fluid away from the vein wall; we called the design the FloRamp;. We created FloRamp prototypes (test device) and tested them against a market-leading device (BD Insyte; control device) in a highly-controlled setting with five insertion sites per device in four pigs. We measured resistance to infusion and visual infusion phlebitis (VIP) every six hours and terminated the experiment at 48 hours. Veins were harvested for histology and seven pathological markers were assessed. Results: Computer simulations showed that the optimum FloRamp tip reduced maximum endothelial shear stress by 60%, from 12.7Pa to 5.1Pa, compared to a typical PIVC tip, and improved the infusion dynamics of saline in the blood stream. In the animal study, we found that 2/5 of the control devices were occluded after 24 hours, whereas all test devices remained patent and functional. The FloRamp created less resistance to infusion (0.73+/-0.81 vs 0.47+/-0.50, p=0.06) and lower VIP scores (0.60+/-0.93 vs 0.31+/-0.70, p=0.09) that the control device, although neither findings were significantly different. Histopathology revealed that 5/7 of the assessed markers were lower in veins with the FloRamp. Conclusions: As PIVCs are used in almost every hospitalized patient, there is an urgent need to reduce failure rates. Herein we report preliminary assessment of a novel PIVC design, which could be advantageous in clinical settings through decreased device occlusion.
Background: Peripheral intravenous catheters (PIVCs) are the most commonly used invasive medical device, yet despite best efforts by end-users, PIVCs experience unacceptably high early failure rates. We aimed to design a new PIVC that reduces the early failure rate of in-dwelling PIVCs and we conducted preliminary tests to assess its efficacy and safety in a porcine model of intravenous access. Methods: We used computer-aided design and simulation to create a PIVC with a ramped tip geometry, which directs the infused fluid away from the vein wall; we called the design the FloRamp™. We created FloRamp prototypes (test device) and tested them against a market-leading device (BD Insyte™; control device) in a highly-controlled setting with five insertion sites per device in four pigs. We measured resistance to infusion and visual infusion phlebitis (VIP) every 6 h and terminated the experiment at 48 h. Veins were harvested for histology and seven pathological markers were assessed. Results: Computer simulations showed that the optimum FloRamp tip reduced maximum endothelial shear stress by 60%, from 12.7 Pa to 5.1 Pa, compared to a typical PIVC tip and improved the infusion dynamics of saline in the blood stream. In the animal study, we found that 2/5 of the control devices were occluded after 24 h, whereas all test devices remained patent and functional. The FloRamp created less resistance to infusion (0.73 ± 0.81 vs 0.47 ± 0.50, p = 0.06) and lower VIP scores (0.60 ± 0.93 vs 0.31 ± 0.70, p = 0.09) than the control device, although neither findings were significantly different. Histopathology revealed that 5/7 of the assessed markers were lower in veins with the FloRamp. Conclusions: Herein we report preliminary assessment of a novel PIVC design, which could be advantageous in clinical settings through decreased device occlusion and reduced early failure rates.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.