Background In the operative treatment of insertional Achilles tendinopathy, the Achilles tendon is often released from its insertion to allow for adequate debridement of pathologic tissue. The use of a double row suture anchor construct has become increasingly favorable among surgeons after Achilles tendon debridement. This study hypothesized that the addition of a Krackow rip stop suture augment to the double row suture anchor construct would increase the repair’s maximum load to failure. A biomechanically stronger repair would potentially decrease the risk of catastrophic failure with early weight-bearing or accidental forced dorsiflexion after operative management for insertional Achilles tendinopathy. Methods Fourteen cadaveric specimens were used to compare the 2 repair techniques. Achilles tendons were debrided and repaired using either a double row suture anchor with and without the additional Krackow rip stop suture augment. The 2 repair techniques were compared using an axial-torsion testing system to measure average load to failure. Results The average load to failure for the double row suture anchor repair alone was 152.00 N. The average load to failure for the tendons with the double row suture anchor with the Krackow rip stop augment was 383.08 N. An independent-samples Mann-Whitney U-test was conducted and the suture anchor plus Krackow augment group had a significantly higher load to failure ( P = .011, Mann-Whitney U = 5.00, n1 = n2 = 7, P < .05, 2-tailed). Conclusion This study confirmed that the addition of a Krakow rip stop augment to the double row suture anchor is able to increase the maximum load to failure when compared to the double row suture anchor alone. These results suggest the potential of this added technique to decrease the risk of catastrophic failure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.