Biologically oriented preparation technique (BOPT) is a vertical preparation technique without a finish line to create a new anatomic crown with a prosthetic emergence profile. This case report describe the protocol realized digitally in a patient who required a new fixed partial denture (FPD) in the anterior esthetic zone. After time of temporary restoration, definitive conventional (CI) (double-cord retraction and vinyl polysiloxane material), and digital impression (DI) with three different intraoral scanner (IOS) (Trios®, True Definition® and iTero®) were taken. All digital impression were obtained through three different scans: temporary restoration in the mouth after healing period, prepared teeth, and temporary restoration out of the mouth. To establish which of the IOS was the most accurate, it was necessary to compare the STL files obtained from each of the IOS with the STL file of the conventional impression, which was digitized with a laboratory scanner (3Shape D800). All these STL were imported to a software (ExoCAD 2.4 Plovdiv®), and they were superimposed. To establish the difference in trueness with SC, 6 points were chosen, 3 points in teeth, and another 3 points in soft tissue. The mean measurement in terms of trueness in teeth were: STS (0,039 mm), SI (0,054 mm), STD (0,067 mm); and in soft tissue were: STS (0,051 mm), SI (0,09 mm), STD [0,236 mm]. The IOSs showed differences between them in terms of trueness, being the Trios the most accuracy IOS. Final restoration was fabricated and cemented. The patient was examined at 3, 6 and 12 months, without any type of biological or mechanical complications. Digital impression with an IOS seems to be a viable alternative to perform zirconia FPD in the BOPT tecbique. Key words: Intraoral scanners, accuracy, vertical preparation, precision, CAD-CAM, prosthodontics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.