Vascular access-related infection is an important adverse event in home hemodialysis (HHD). We hypothesize that errors in self-cannulation or manipulation of dialysis vascular access are associated with increased incidence of access-related infection. We conducted a retrospective cohort study of all prevalent HHD patients at the University Health Network. All vascular access-related infections were recorded from 2006 to 2013. Errors in dialysis access were ascertained by nurse-administered vascular access checklist. Ninety-two patients had completed at least one vascular access audit. Median HHD vintage was 2.3 (0.9-5.0) years in patients with appropriate vascular access technique and 5.8 (1.5-9.4) years in patients with erroneous vascular access technique. The overall rate of infection between patients with and without appropriate vascular access technique was similar (0.27 and 0.28 infections per year, P = 0.166). Among patients who were identified with errors in dialysis access manipulation, patients with five or more errors were associated with higher rate of access-related infection (mean of 0.47 vs. 0.16 infection per patient-year, P < 0.001). The use of vascular access audit is a feasible strategy, which can identify errors in vascular access technique. Patients with a longer median HHD vintage are associated with higher risk of inappropriate vascular access technique. Patients with multiple errors in vascular access technique are associated with a higher risk of dialysis access-related infection. Prospective evaluation of the impact of vascular access audit on adverse vascular access events is warranted.
We present a case of a patient on home hemodialysis who developed Mycobacterium mucogenicum bacteremia. While infections with this particular organism are rare, disseminated infections have been reported and have been associated with significant morbidity and mortality. Diagnosis required appropriate cultures, understanding of natural habitat of organism and complete environmental analysis including blood, dialysis sample port, reverse osmosis and incoming water supply cultures. The patient was treated successfully with systemic antibiotics, removal of central venous catheter, patient education and complete exchange of the hemodialysis circuit.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.