Fluorine, chlorine, bromine, and iodine have been studied in biological samples and other related matrices owing to the need to understand the biochemical effects in living organisms. In this review, the works published in last 20 years are covered, and the main topics related to sample preparation methods and analytical techniques commonly used for fluorine, chlorine, bromine, and iodine determination in biological samples, food, drugs, and plants used as food or with medical applications are discussed. The commonest sample preparation methods, as extraction and decomposition using combustion and pyrohydrolysis, are reviewed, as well as spectrometric and electroanalytical techniques, spectrophotometry, total reflection X-ray fluorescence, neutron activation analysis, and separation systems using chromatography and electrophoresis. On this aspect, the main analytical challenges and drawbacks are highlighted. A discussion related to the availability of certified reference materials for evaluation of accuracy is also included, as well as a discussion of the official methods used as references for the determination of halogens in the samples covered in this review.
Iodine determination in food samples was performed by inductively coupled plasma mass spectrometry (ICP-MS) after digestion by microwave-induced combustion (MIC). Sample masses up to 500 mg of bovine liver, corn starch, milk powder, or wheat flour were completely combusted using the MIC system. Ammonium nitrate (6 mol l(-1) solution, 50 μl) was used as an aid for ignition and vessels were charged with 15 bar of O(2). The use of H(2)O, 0.9 mmol l(-1) H(2)O(2), 10 to 50 mmol l(-1) (NH(4))(2)CO(3) and 56 mmol l(-1) tetramethylammonium hydroxide was investigated as absorbing solutions, as well as the suitability of performing a reflux step after the combustion process. Digestion of food samples by pressurized microwave-assisted acid digestion, microwave-assisted extraction and conventional extraction of iodine in alkaline solution were also evaluated. Iodine recoveries higher than 99% were obtained using MIC and 50 mmol l(-1) (NH(4))(2)CO(3) or 56 mmol l(-1) tetramethylammonium hydroxide as absorbing solution and with 5 min for the reflux step. Accuracy was evaluated using certified reference materials (bovine muscle, corn bran, and milk powder) and agreement better than 97% was obtained. The limit of quantification by MIC and further ICP-MS determination was 0.002 µg g(-1). Blanks were always low and no memory effects were observed. Digestion by MIC allowed the processing of up to eight samples by each run in 25 min with high efficiency of digestion (residual carbon content lower than 1%) providing a suitable medium for further iodine determination by ICP-MS.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.