The ultrasonic mold was designed for the ceramic powder compression. CAD and CAE were used in the design to analyze the mold strength and its natural frequency. The study of stress distribution and compression in upper and lower punch, mold body and waveguide comparison of stresses was analyzed by FEA experiments under maximum compression at 50,000 N to validate the results of both methods and the mold natural frequency. The difference between FEA and experimental analysis was 3-7%, acceptable. The redesign results in a cylindrical mold body with the outer diameter of 80 mm, the height of 100 mm, and the upper punch of 125 mm in length. The six sides are 26 mm of the high waveguide with 100 mm height. The internal and external diameters are 80 and 110 mm, respectively. The mold has been redesigned and can support the maximum compression force of 1,500 kN. with the bearing steel, AISI 52100, obtainable hardness 65 HRC, the stress concentration occurs at the neck of the upper punch using the ultrasonic at 12.00 to 12.45 kHz.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.