PurposeTo evaluate the minimum 5-year mid-term clinical and radiological results of minimally invasive surgery total knee arthroplasty (MIS-TKA) using a mini-keel modular tibia component.Materials and MethodsWe retrospectively evaluated 254 patients (361 cases) who underwent MIS-TKA between 2005 and 2006. The latest clinical and radiological assessments were done in 168 cases that had been followed on an outpatient basis for more than 5 postoperative years. Clinical results were assessed using the Hospital for Special Surgery (HSS) score and Knee Society score. Radiological evaluation included measurements of knee alignment.ResultsThe average postoperative knee range of motion and HSS score were 134.3°±12.4° and 92.7°±7.0°, respectively. The average postoperative femorotibial angle and tibial component alignment angle were 5.2°±1.7° valgus and 90.2°±1.6°, respectively. The average tibial component posterior inclination was 4.8°±2.1°. The percentage of cases with tibial component alignment angle of 90°±3° was 96.1%, and that with the femorotibial angle of 6°±3° valgus was 94.0%. Radiolucent lines were observed in 20 cases (12.0%): around the femur, tibia, and patella in 14 cases, 10 cases, and 1 case, respectively. However, they were less than 2 mm and non-progressive in all cases. The survival rate was 99.4% and there was no implant-related revision.ConclusionsMIS-TKA using a mini-keel modular tibial plate showed satisfactory results, a high survival rate, and excellent clinical and radiological results in the mid-term follow-up.
PurposeThe aim of this study was to report the long-term outcome and the failure mechanism of cementless total hip arthroplasty (THA) using hydroxyapatite (HA)-coated acetabular cup.Materials and MethodsFrom January 1992 to May 1994, a total of 123 consecutive cementless primary THAs were performed using a HA-coated acetabular cup with metal-on-polyethylene articulation. We retrospectively evaluated 66 hips available for follow-up at a mean 18.3 years (range, 10.4-23.6 years). The survival analysis was performed by the Kaplan-Meier method. We defined end point as any failure that required a reoperation of acetabular component.ResultsThirty-nine of 66 hips (59.1%) were defined as a failure for progressive acetabular osteolysis or aseptic loosening of the cup. Acetabular osteolysis was observed in 47 hips (71.2%) and 33 hips (50.0%) were revised because of cup loosening. The Kaplan-Meier method showed the survival rate of the acetabular cup to be 46.3% at 15 years and 34.8% at 20 years for any failure that required a reoperation of acetabular component.ConclusionThe long-term survival rate of THA using HA-coated acetabular cup was unsatisfactory, and it was attributed to vulnerable property of HA coating and progressive osteolysis.
PurposeTo identify the accuracy of postoperative implant alignment in minimally invasive surgery total knee arthroplasty (MIS-TKA), based on the degree of varus deformity.Materials and MethodsThe research examined 627 cases of MIS-TKA from November 2005 to December 2007. The cases were categorized according to the preoperative degree of varus deformity in the knee joint in order to compare the postoperative alignment of the implant: less than 5° varus (Group 1, 351 cases), 5° to less than 10° varus (Group 2, 189 cases), 10° to less than 15° varus (Group 3, 59 cases), and 15° varus or more (Group 4, 28 cases).ResultsOn average, the alignment of the tibial implant was 0.2±1.4°, 0.1±1.3°, 0.1±1.6°, and 0.3±1.7° varus, and the tibiofemoral alignment was 5.2±1.9°, 4.7±1.9°, 4.9±1.9°, and 5.1±2.0° valgus for Groups 1, 2, 3, and 4, respectively, in the preoperative stage, indicating no difference between the groups (p>0.05). With respect to the accuracy of the tibial implant alignment, 98.1%, 97.6%, 87.5%, and 86.7% of Groups 1, 2, 3, and 4, respectively, had 0±3° varus angulation, demonstrating a reduced level of accuracy in Groups 3 and 4 (p<0.0001). There was no difference in terms of tibiofemoral alignment, with 83.9%, 82.9%, 85.4%, and 86.7% of each group, respectively, showing 6±3° valgus angulation (p>0.05).ConclusionSatisfactory component alignment was achieved in minimally invasive surgery in total knee arthroplasty, regardless of the degree of varus deformity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.