Stroke survivors with gait disturbances may use ankle foot orthoses (AFOs). However, most AFOs come in one-piece styles, which make it difficult for spasticity-affected stroke survivors to don. AFOs are also limited since they do not properly prevent ankle joint for foot drop by itself. Therefore, the present study developed a novel hinged AFO by adding a locking device to a hinged joint. We then tested its feasibility in 9 hemiplegic stroke survivors by investigating temporalspatial gait parameters using the GAITRite in the following 3 conditions: no AFO, traditional AFO, and novel hinged AFO. There was no significant difference in spatiotemporal gait parameters among the different conditions. There were greater decreases in gait velocity, cadence, step length, and stride length in the novel hinged AFO group than in the no AFO and traditional AFO groups. This novel hinged AFO was developed to prevent foot drop. However, the AFO did not show significant differences in gait parameters because it consists of metal with extra weight and volume. Functionally, it prevented foot drop. It also improved convenience by its releasable design. Thus, further studies are needed to develop an AFO that improves gait and is convenient to use for hemiplegic stroke survivors.
The elderly population in many countries has been rising rapidly, and falls are a serious event many elderly people experience. Assistive equipment is actively used to reduce falls among elderly people. Popular types of assistive equipment include canes, electric wheelchairs, and wheeled walkers. Wheeled walkers support the body of elderly people, making their gait comfortable as they age or recover from injuries. Wheeled walkers may be equipped with hand brakes; however, frail older people may experience difficulty using such hand brakes, as they require force to operate. Thus, in the present study, a braking method using a wire connected to a user's belt or clothes was designed and implemented; if the tension of the wire connecting the safety device and the user exceeds a critical value, the wheeled walker brakes, which can prevent the rapid motion of walkers. Two feasibility tests of the wheeled walker with the braking device were conducted: one with 10 healthy adults in their 20s and the other with 10 elderly people over 65 years of age; the tests measured the braking time and speed control using a speed measuring device. The results of the first and second feasibility tests demonstrated that the average braking time of participants was 50.3 ms and 50.7 ms, respectively. All participants in the feasibility tests succeeded in the speed control test. Thus, based on the results, the braking device on the wheeled walker worked properly.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.