We investigated the effect of the optical blurring of X-ray source on digital breast tomosynthesis (DBT) image quality using well-designed DBT simulator and table-top experimental systems. To measure the in-plane modulation transfer function (MTF), we used simulated sphere phantom and Teflon sphere phantom and generated their projection data using two acquisition modes (i.e., step-and-shoot mode and continuous mode). After reconstruction, we measured the in-plane MTF using reconstructed sphere phantom images. In addition, we measured the anatomical noise power spectrum (aNPS) and signal detectability. We constructed simulated breast phantoms with a 50% volume glandular fraction (VGF) of breast anatomy using the power law spectrum and inserted spherical objects with 1 mm, 2 mm, and 5 mm diameters as breast masses. Projection data were acquired using two acquisition modes, and in-plane breast images were reconstructed using the Feldkamp-Davis-Kress (FDK) algorithm. For the experimental study, we used BR3D breast phantom with 50% VGF and obtained projection data using a table-top experimental system. To compare the detection performance of the two acquisition modes, we calculated the signal detectability using the channelized Hotelling observer (CHO) with Laguerre-Gauss (LG) channels. Our results show that spatial resolution of in-plane image in continuous mode was degraded due to the optical blurring of X-ray source. This blurring effect was reflected in aNPS, resulting in large β values. From a signal detectability perspective, the signal detectability in step-and-shoot mode is higher than that in continuous mode for small spherical signals but not large spherical signals. Although the step-and-shoot mode has disadvantage in terms of scan time compared to the continuous mode, scanning in step-and-shoot mode is better for detecting small signals, indicating that there is a tradeoff between scan time and image quality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.