(1) Background: We performed this study to evaluate the agreement between novel automated software of three-dimensional transesophageal echocardiography (3D-TEE) and multidetector computed tomography (MDCT) for aortic annular measurements of preprocedural transcatheter aortic valve replacement (TAVR); (2) Methods: PubMed, EMBASE, Web of Science, and Cochrane Library (Wiley) databases were systematically searched for studies that compared 3D-TEE and MDCT as the reference standard for aortic annular measurement of the following parameters: annular area, annular perimeter, area derived-diameter, perimeter derived-diameter, maximum and minimum diameter. Meta-analytic methods were utilized to determine the pooled correlations and mean differences between 3D-TEE and MDCT. Heterogeneity and publication bias were also assessed. Meta-regression analyses were performed based on the potential factors affecting the correlation of aortic annular area; (3) Results: A total of 889 patients from 10 studies were included in the meta-analysis. Pooled correlation coefficients between 3D-TEE and MDCT of annulus area, perimeter, area derived-diameter, perimeter derived-diameter, maximum and minimum diameter measurements were strong 0.89 (95% CI: 0.84–0.92), 0.88 (95% CI: 0.83–0.92), 0.87 (95% CI: 0.77–0.93), 0.87 (95% CI: 0.77–0.93), 0.79 (95% CI: 0.64–0.87), and 0.75 (95% CI: 0.61–0.84) (Overall p < 0.0001), respectively. Pooled mean differences between 3D-TEE and MDCT of annulus area, perimeter, area derived-diameter, perimeter derived-diameter, maximum and minimum diameter measurements were −20.01 mm2 ((95% CI: −35.37 to −0.64), p = 0.011), −2.31 mm ((95% CI: −3.31 to −1.31), p < 0.0001), −0.22 mm ((95% CI: −0.73 to 0.29), p = 0.40), −0.47 mm ((95% CI: −1.06 to 0.12), p = 0.12), −1.36 mm ((95% CI: −2.43 to −0.30), p = 0.012), and 0.31 mm ((95% CI: −0.15 to 0.77), p = 0.18), respectively. There were no statistically significant associations with the baseline patient characteristics of sex, age, left ventricular ejection fraction, mean transaortic gradient, and aortic valve area to the correlation between 3D-TEE and MDCT for aortic annular area sizing; (4) Conclusions: The present study implies that 3D-TEE using novel software tools, automatically analysis, is feasible to MDCT for annulus sizing in clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.