Paper works: Paper‐based indirect ELISA (see picture) has been demonstrated through the detection of rabbit IgG and the HIV‐1 envelope antigen gp41. This technique combines the sensitivity and specificity of ELISA with the low cost and ease‐of‐use of paper‐based platforms.
This communication demonstrates the generation of over 300 phase-separated systems—ranging from two to six phases—from mixtures of aqueous solutions of polymers and surfactants. These aqueous multiphase systems (MuPSs) form self-assembling, thermodynamically stable, step-gradients in density using a common solvent (water). The steps in density between phases of a MuPS can be very small (Δρ ~ 0.001 g/cm3), do not change over time, and can be tuned by the addition of co-solutes. We use two sets of similar objects—glass beads and pellets of different formulations of Nylon—to demonstrate the ability of MuPSs to separate mixtures of objects by differences in density. The stable interfaces between phases facilitate the convenient collection of species after separation. These results suggest that the stable, sharp, step-gradients in density provided by MuPSs can enable new classes of fractionations and separations based on density.
# These authors contributed equally to this work.1 This paper describes enzyme-linked immunosorbent assays (ELISA) performed in a 96-microzone plate made out of paper (paper-based ELISA, or P-ELISA). ELISA is widely used in biochemical analyses, including immunoassays, food industry assays for food allergens, and toxicological assays. These assays are typically carried out in microtiter plates or small vials.1,2 ELISA combines the specificity of antibodies and the high-turnover catalysis by enzymes, to provide specificity and sensitivity. 1,2 We have recently described a 96-microzone paper plate-fabricated by patterning hydrophobic polymer in hydrophilic paper-as a platform for biochemical analysis. 3,4 Although microfluidic paper-based analytical devices (µPADs) were designed primarily to provide analytical capability at low cost in developing countries, [5][6][7] we expect that they will also be useful in applications such as point-of-care clinical analysis, military field operations, and others where high throughput, low volumes of sample, low cost, and robustness are important. 6,7 These devices have so far been prototyped using analyses of simple metabolites: glucose, protein, and certain enzymes. 8-10 P-ELISA combines the sensitivity and specificity of ELISA with the convenience, low cost and ease-of-use of paper-based platforms.Porous membranes, including nitrocellulose and filter paper, have been used for decades in dot-immunobinding assays (DIA). [8][9][10][11][12][13] Though DIAs are the simplest form of immunoassays on paper, they typically require one piece of nitrocellulose for each assay, the pieces of nitrocellulose have to be processed individually in Petri dishes, and the assays take several hours to complete. 9 Quantitative DIAs have been reported, 14 but DIAs are typically qualitative, and provide only "yes/no" results. 15 Traditional ELISA, usually performed in 96-well plates (fabricated by injection molding in plastic), is quantitative 2 and well-suited for high-throughput assays, but each assay requires large volumes (~20-200 µL) of analyte and reagents, the incubation and blocking steps are long (≥1 h per step, because the reagents must diffuse to the surface of the wells), and the results are quantified using a plate reader, typically an ~$20,000 instrument. 9,16Paper microzone plates for ELISA can have the same layout as plastic 96-wellplates, but each test zone requires only ~3 µL of sample, and the results can be measured using a desktop scanner, typically a ~$100 instrument. In addition, an entire P-ELISA can be completed in less than one hour. The ease of fabrication of paper microzone plates also opens opportunities for a wide range of non-standard formats, and customized connections to carry reagents between zones. To evaluate the feasibility of P-ELISA, and the potential advantages and disadvantages of P-ELISA and 96-well-plate-based ELISA,we developed a three-step procedure that i) immobilizes targeted antigens and then incubates them with their primary antibodies on a 96-microzo...
This paper demonstrates the use of aqueous multiphase systems (MuPSs) as media for rate-zonal centrifugation to separate nanoparticles of different shapes and sizes. The properties of MuPSs do not change with time or during centrifugation; this stability facilitates sample collection after separation. A three-phase system demonstrates the separation of the reaction products (nanorods, nanospheres, and large particles) of a synthesis of gold nanorods, and enriches the nanorods from 48 to 99% in less than ten minutes using a benchtop centrifuge.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.