Objective. Spinal cord neuromodulation has gained much attention for demonstrating improved motor recovery in people with spinal cord injury, motivating the development of clinically applicable technologies. Among them, transcutaneous spinal cord stimulation (tSCS) is attractive because of its non-invasive profile. Many tSCS studies employ a high-frequency (10 kHz) carrier, which has been reported to reduce stimulation discomfort. However, these claims have come under scrutiny in recent years. The purpose of this study was to determine whether using a high-frequency carrier for tSCS is more comfortable at therapeutic amplitudes, which evoke posterior root-muscle (PRM) reflexes. Approach. In 16 neurologically intact participants, tSCS was delivered using a 1-ms long monophasic pulse with and without a high-frequency carrier. Stimulation amplitude and pulse duration were varied and PRM reflexes were recorded from the soleus, gastrocnemius, and tibialis anterior muscles. Participants rated their discomfort during stimulation from 0-10 at PRM reflex threshold. Main Results. At PRM reflex threshold, the addition of a high-frequency stimulation (0.87 ± 0.2) was equally comfortable as conventional stimulation (1.03 ± 0.18) but required approximately double the charge to evoke the PRM reflex (conventional: 32.4 ± 9.2 µC; high-frequency carrier: 62.5 ± 11.1 µC). Strength-duration curves for tSCS with a high-frequency carrier had a rheobase that was 4.8X greater and a chronaxie that was 5.7X narrower than the conventional monophasic pulse, indicating that the addition of a high-frequency carrier makes stimulation was less efficient in recruiting neural activity in spinal roots. Significance. Using a high-frequency carrier for tSCS is equally as comfortable and less efficient as conventional stimulation at amplitudes required to stimulate spinal dorsal roots.
Spinal cord neuromodulation has gained much attention for demonstrating improved motor recovery in people with spinal cord injury, motivating the development of clinically applicable technologies. Among them, transcutaneous spinal cord stimulation (tSCS) is attractive because of its non-invasive profile. Many tSCS studies employ a high-frequency (10 kHz) carrier, which has been reported to reduce stimulation discomfort. However, these claims have come under scrutiny in recent years. The purpose of this study was to determine whether high-frequency tSCS is more comfortable at therapeutic amplitudes, which evoke posterior root-muscle (PRM) reflexes. In 16 neurologically intact participants, tSCS was delivered using a 1-ms long monophasic pulse with and without a high-frequency carrier. Stimulation amplitude and pulse duration were varied and PRM reflexes were recorded from the soleus, gastrocnemius, and tibialis anterior muscles. Participants rated their discomfort during stimulation from 0-10 at PRM reflex threshold. At PRM reflex threshold, high-frequency stimulation (0.87 ± 0.2) was equally comfortable as conventional stimulation (1.03 ± 0.18) but required approximately double the charge to evoke the PRM reflex (conventional: 32.4 ± 9.2 μC; high-frequency: 62.5 ± 11.1 μC). Strength-duration curves for high-frequency stimulation had a rheobase that was 4.8X greater and a chronaxie that was 5.7X narrower than the conventional monophasic pulse, indicating that high-frequency stimulation was less efficient in recruiting neural activity in spinal roots. High-frequency tSCS is equally as comfortable as conventional stimulation at amplitudes required to stimulate spinal dorsal roots.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.