The SARC-F scale can identify old Chinese people with impaired physical function who may suffered from sarcopenia. SARC-F judgment reflects fear of falling, indicates the hospitalization events and is associated with ability of daily life. Thus, SARC-F may be a simple and useful tool for screening individuals with impaired physical function. Further studies on SARC-F in Chinese people would be worthy.
Based on ET opening detection rates, we recommend the use of dry swallows with sonotubometry and the nine-step test. When testing patient-reported opening and observed membrane movement, and when performing Tubo-tympano-aerodynamic-graphy and impedance tests, we recommend the use of Valsalva maneuvers. Further studies are required to explore the association between the test technique and results in ears with ET dysfunction.
Objective Eustachian tube (ET) dysfunction is most frequently caused by a failure of the ET to adequately open; however, there is currently no reliable method of assessing this. Tubomanometry has recently shown good interindividual repeatability as a measure of ET function by measuring middle ear pressure after the application of regulated nasopharyngeal pressures during swallowing. We present the first reports of a novel test: middle ear impedance measurements during standard nasopharyngeal pressure application (tuboimpedance). We assess repeatability in healthy ears and any advantages over tubomanometry. Study Design Exploratory cohort diagnosis study. Setting Tertiary referral center. Subjects Twenty screened, healthy ears (10 volunteers). Methods Tubomanometry and tuboimpedance tests were performed while individuals swallowed with applied nasopharyngeal pressures of 20, 30, 40, and 50 mbar. Eustachian tube opening detection rate and test repeatability (measured by intraclass correlation coefficient [ICC]) for immediate and delayed repeats at each pressure were compared. Results ET opening was detected more frequently using tuboimpedance, with a 100% detection rate using a nasopharyngeal pressure of 30 mbar or more, compared to 88% to 96% with tubomanometry. Detection of ET opening at 20 mbar was possible with tuboimpedance. Repeatability of both tests was mostly strong (ICC >0.7) for both immediate and delayed repeats. Repeatability for the tubomanometry R value was only fair to moderate. Conclusion Tuboimpedance may provide a repeatable measure of ET opening that is easier to perform due to lower nasopharyngeal pressures required and fewer issues with poor ear-probe sealing. Further assessment in patients with different forms of ET dysfunction is required.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.