Background. We aimed to validate an easy-to-use videofluoroscopic analysis tool, the bolus residue scale (BRS), for detection and classification of pharyngeal retention in the valleculae, piriform sinuses, and/or the posterior pharyngeal wall. Methods. 50 randomly selected videofluoroscopic images of 10 mL swallows (recorded in 18 dysphagia patients and 8 controls) were analyzed by 4 experts and 6 nonexpert observers. A score from 1 to 6 was assigned according to the number of structures affected by residue. Inter- and intrarater reliabilities were assessed by calculation of intraclass correlation coefficients (ICCs) for expert and nonexpert observers. Sensitivity, specificity, and interrater agreement were analyzed for different BRS levels. Results. Intrarater reproducibility was almost perfect for experts (mean ICC 0.972) and ranged from substantial to almost perfect for nonexperts (mean ICC 0.835). Interjudge agreement of the experts ranged from substantial to almost perfect (mean ICC 0.780), but interrater reliability of nonexperts ranged from substantial to good (mean 0.719). BRS shows for experts a high specificity and sensitivity and for nonexperts a low sensitivity and high specificity. Conclusions. The BRS is a simple, easy-to-carry-out, and accessible rating scale to locate pharyngeal retention on videofluoroscopic images with a good specificity and reproducibility for observers of different expertise levels.
Hypothesis: Intracochlear pressure (ICP) measurements during bone conduction (BC) stimulation may be affected by motion of the pressure sensor relative to the cochlear promontory bone, demonstrating the need to cement the sensor firmly to the cochlear bone. Background: ICP is a promising measurement tool for investigating the cochlear drive in BC transmission, but its use is not yet standardized. Previous ICP studies have reported artificially increased pressure due to motion of the sensor relative to the temporal bone. The artifact can be reduced by firmly cementing the sensor to the bone, but this is destructive for the sensor. Previous studies used a custom-made sensor; the use of commercially available sensors, however, is more generic, but also more challenging to combine with the cement. Therefore, the goals of the current study are: firstly, to evaluate a non-destructive cementing method suitable for a commercially available sensor, and secondly, to investigate ICP measurements during BC stimulation in more detail. Methods: To study the effect of sensor cementing, three fixation conditions were investigated on six fresh-frozen temporal bones: 1) alginate, 2) alginate and dental composite, 3) alginate and dental composite, released from micromanipulators. Pressures in scala tympani and vestibuli were measured simultaneously, while velocity measurements were performed on the cochlear promontory and sensor. The ratio between sensor and promontory bone velocity was computed to quantify the relative motion. Results: For air conduction stimulation, results were in line with those from previous ICP studies, indicating that baseline measurements were valid and could be used to interpret the results obtained with BC stimulation. Results showed that cementing the sensors and releasing them from the micromanipulators is crucial for valid ICP measurements. When the sensors were only sealed with alginate, the pressure was overestimated, especially at low and mid-frequencies. When the sensors were cemented and held in the micromanipulators, the pressure was underestimated. Compared with the scala tympani measurements, ICP measurements showed a lower scala vestibuli pressure below 1 kHz, and a higher pressure above 1 kHz. Conclusion: Dental composite is effective as a cement to attach commercially available sensors to the cochlear promontory bone. When sensors are firmly attached, valid ICP measurements can be obtained with BC stimulation.
Recent findings support the efficacy of the direct acoustic cochlear implant (DACI) in patients with advanced otosclerosis whose rehabilitation is very challenging. Standard treatment consists of stapes surgery combined with hearing aids or a cochlear implant (CI). CI surgery, however, is often challenging depending on the grade of otosclerosis. This study aims to compare speech perception scores in quiet and noise of 6 DACI and 12 CI patients with advanced otosclerosis at 3 and 12 months after fitting. Preoperative computed tomographic scans of all patients were scored by experts using an existing otosclerosis grading system (stages 1–3). Speech perception in quiet was significantly better for DACI compared to CI users at 3 months after fitting. At 12 months, no difference was found between DACI and CI patients. Speech perception scores in noise were significantly better in the DACI group. In summary, a DACI system seems to provide an effective treatment option as the acoustic component can be preserved in patients with advanced otosclerosis.
Active transcutaneous bone conduction (BC) devices offer the benefit of improved power output compared to passive transcutaneous devices and remove the risk of skin infections that are more common in traditional percutaneous BC devices. Despite these advantages, more research is needed on implant location, device coupling, and their influence on device performance. This study is aimed at quantifying the extent to which certain parameters affect device output when using the Osia® system actuator. Parameters under study are (1) implant location, (2) comparison with the actuator of a state-of-the-art BC device, (3) bone undergrowth simulation, and (4) skull fixation. Five human cadaveric heads were implanted with the actuator at three different implant locations: (1) recommended, (2) posterior Osia® positions, and (3) standard Baha® position. At each location, the cochlear promontory velocity and the intracochlear pressure difference were measured. A percutaneous bone conduction actuator was used as a reference for the obtained measurements. Stimulation levels corresponded to a hearing level of 60 dB HL for frequencies between 250 and 6000 Hz. In addition, bone cement was used as a simulation for reactive bone growth. Results obtained in four heads indicate an improved power transmission of the transcutaneous actuator when implanted at the recommended position compared to the actuator of the percutaneous device on its respective recommended location when stimulating at an identical force level. A correlation was found between the promontory vibration and the actuator position, indicating that the same level of stimulation leads to higher promontory vibrations when the device is implanted closer to the ear canal. This is mainly reflected at frequencies higher than 1 kHz, where an increase was observed in both measurement modalities. At lower frequencies (<1 kHz), the power transmission is less influenced by the implant position and differences between the acquired responses are limited. In addition, when no rigid coupling to the skull is provided, power transfer losses of up to 30 dB can be expected.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.