Introduction. The aim of this study was to determine the effect on the flexural strength of the self-cured acrylic resin by incorporating short E-glass fiber (SEGF) and ultra-high-molecular-weight polyethylene (UHMW-PE) filler in the acrylic resin. Methods. Fifty-six rectangular (64 × 10 × 3.3 mm3) (ISO standard 20795–1:2013) self-cured acrylic resin specimens were fabricated and divided into seven groups per test, according to the percent by weight of SEGF and UHMW-PE filler (n = 8). Each testing group entails a control group and an addition of 1% and 2% SEGF, 1% and 2% UHMW-PE, 0.5% SEGF/UHMW-PE, and 1% SEGF/UHMW-PE. A three-point bending test was conducted to obtain the flexural strength of each specimen. The fractured surfaces of the specimens were evaluated, and a scanning electron microscope view was taken. Test results were statistically analyzed with one-way ANOVA and Tukey HSD tests ( p value<0.05). Results. The flexural strength of self-cured acrylic resin with the addition of 1% SEGF and 1% SEGF/UHMW-PE (50.93, 46.13 MPa) was significantly higher than that of the control group (41.72 MPa) ( p < 0.05 ). Nonetheless, the addition of 1% UHMW-PE (39.34 MPa) showed the lowest flexural strength, significantly lower than other experimental groups, except the control group. Conclusion. The addition of 1% SEGF significantly improves the flexural strength of the self-cured acrylic resin denture base.
The aim of this study was to analyze the effect of applying short E-glass fiber (SEG) and ultrahigh molecular weight polyethylene (UWPE) filler on the shear bond strength between the repaired surface of the rapid heat-cured and the reinforced autopolymerized acrylic resin. Fifty-six circular (15 × 3.3 mm2) rapid heat-cured resins were made and assigned equally to seven different groups. These were later bonded to fifty-six circular-reinforced autopolymerized acrylic resin specimens. Every test group included a control group, along with applying 1% and 2% SEG, 0.5% SEG/UWPE, 1% SEG/UWPE, and 1% and 2% UWPE. The universal testing machine was utilized to conduct the shear bond strength test. The repaired surface of these samples was assessed. Besides, the mode of failure was visualized under stereo microscope. The shear bond strength of all experimental groups was significantly higher than that of the control group. Group 3 with the addition of 1% SEG demonstrated the highest significance (12.86 MPa). The mode of failure for most of specimens was a mixed failure. Thus, it is indicated that enhancing the resin with 1% short E-glass fiber significantly improves the shear bond strength between repaired surface of the rapid heat-cured acrylic resin denture base and the reinforced autopolymerized acrylic resin.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.