Purpose: Characterization of a novel dual‐panel PET scanner for use in small animal imaging. Method and Materials: A prototype PET system comprised of two non‐rotating HRRT panel detectors — each possessing a single‐layer 72 × 104 array of 2.1mm × 2.1mm × 7.5mm LSO crystals — was evaluated for its suitability in small animal imaging. Resolution measurements were made by translating a 190mm long, 3mm diameter 21.5MBq 〈sup〉68〈/sup〉Ge line‐source across various planes parallel to the detector's face, while sensitivity measurements were made in a similar fashion but using a 0.5mm diameter 65KBq 〈sup〉68〈/sup〉Ge point‐source. To emulate small animal imaging, a mouse phantom was constructed from an 11.25mm length of 25.4mm diameter polycarbonate rod that contained a 3.5mm diameter hole — radially offset by 6.7mm and parallel to the rod's central axis — to accommodate either the 〈sup〉68〈/sup〉Ge line‐source or 〈sup〉18〈/sup〉FDG samples. Results: Activity‐independent scattered fractions were estimated by inserting the 〈sup〉68〈/sup〉Ge line‐source into the mouse phantom, averaging counts in each crystal column parallel to the line‐source, and second‐order polynomial fitting the resulting projection data after excluding its central peak. Noise Equivalent Count Rates (NECRs) were then derived for various energy windows and 〈sup〉18〈/sup〉FDG activities in the mouse phantom, to quantify scanner performance. Preliminary image reconstructions, performed using a 50‐iteration Expectation Maximization algorithm, demonstrated reconstruction resolutions of ∼1.6mm. Sensitivity measurements exhibited significant dependence upon energy window selection; with the 250–750keV energy window resulting in both the highest absolute sensitivity (6.8%) and the highest NECR (142kcps at 1.25MBq/cc). Conclusion: Although the measured sensitivity's energy dependence suggests additional energy calibrations are needed, preliminary data show both device sensitivity and resolution to be comparable to or better than that of current commercial systems. Moreover the dual‐panel scanner's simple fixed geometry and large field‐of‐view are especially well suited for whole‐body imaging and concurrent imaging of multiple animals.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.