In this paper, a numerical analysis coupling heat transfers of the combustor internal flow, the coolant flow and the strut wall is developed and applied for the optimization of strut cooling using aviation kerosene as coolant at flow conditions corresponding to the combustor entrance condition for Mach 6 scramjet flight. The coupling procedure is tested and proven to be an efficient method of being capable to obtain the converged temperature and heat transfer solutions of the cooled strut within a few iteration steps. Four cooling designs with varied diameter, length and position of the cooling channels are investigated and their improvements on fuel injection and mixing are also verified compared to the wall injection. The kerosene-cooled strut (Strut4) is tested in a Mach 2.5 supersonic tunnel with inlet total temperature and total pressure of 1900K and 1.45MPa respectively for 60 seconds. The damaged part in the upper leading edge of the strut is observed, which is consistent with the result obtained by the numerical analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.