Background. Radiation using conventional X-ray is associated with exposure of radiosensitive organs and typically requires the use of protection. This study is aimed at evaluating the use of bismuth shielding for radiation protection in pediatric pelvic radiography. The effects of the anteroposterior and lateral bismuth shielding were verified by direct measurements at the anatomical position of the gonads. Methods. Radiation doses were measured using optically stimulated luminescence dosimeters (OSLD) and CIRS ATOM Dosimetry Verification Phantoms. Gonad radiographs were acquired using different shields of varying material (lead, bismuth) and thickness and were compared with radiographs obtained without shielding to examine the effects on image quality and optimal reduction of radiation dose. All images were evaluated separately by three pediatric orthopedic practitioners. Results. Results showed that conventional lead gonadal shielding reduces radiation doses by 67.45%, whereas dose reduction using one layer of bismuth shielding is 76.38%. The use of two layers of bismuth shielding reduces the dose by 84.01%. Using three and four layers of bismuth shielding reduces dose by 97.33% and 99.34%, respectively. Progressively lower radiation doses can be achieved by increasing the number of bismuth layers. Images obtained using both one and two layers of bismuth shielding provided adequate diagnostic information, but those obtained using three or four layers of bismuth shielding were inadequate for diagnosis. Conclusions. Bismuth shielding reduces radiation dose exposure providing appropriate protection for children undergoing pelvic radiography. The bismuth shielding material is lighter than lead, making pediatric patients more comfortable and less apt to move, thereby avoiding repeat radiography.
We sought to design a computer-assisted system measuring the anterior tibial translation in stress radiography, evaluate its diagnostic performance for an anterior cruciate ligament (ACL) tear, and assess factors affecting the diagnostic accuracy. Retrospective research for patients with both knee stress radiography and magnetic resonance imaging (MRI) at our institution was performed. A complete ACL rupture was confirmed on an MRI. The anterior tibial translations with four different methods were measured in 249 patients by the designed algorithm. The diagnostic accuracy of each method in patients with all successful measurements was evaluated. Univariate logistic regression analysis for factors affecting diagnostic accuracy of method four was performed. In the inclusive 249 patients, 177 patients (129 with completely torn ACLs) were available for analysis. Mean anterior tibial translations were significantly increased in the patients with a completely torn ACL by all four methods, with diagnostic accuracies ranging from 66.7% to 75.1%. The diagnostic accuracy of method four was negatively associated with the time interval between stress radiography and MRI as well as force-joint distance on stress view, and not significantly associated with age, gender, flexion angle, intercondylar distance, and force-joint angle. A computer-assisted system measuring the anterior tibial translation in stress radiography showed acceptable diagnostic performance of complete ACL injury. A shorter time interval between stress radiography and MRI as well as shorter force-joint distance were associated with higher diagnostic accuracy.
Background: Diagnostic accuracy of double-contrast barium enema (DCBE) depends upon the barium sulfate coating efficiency in the colon. Objective: To evaluate effects of three laxatives on barium sulfate coating efficiency in the large intestine, sigmoid colon, and hepatic flexure in DCBE. Methods: This retrospective study included patients receiving DCBE after pre-procedure cleansing with Dulcolax® with castor oil (DC), Klean-Prep® (KP), or Fleet®. Patients’ DCBE images were reviewed. Results: Among 373 cases of DCBE, 151 received DC, 147 received KP, and 75 received Fleet. For DCBE, the optimal extent of barium sulfate residue coated on the wall of the large intestine is less than one-fourth of bowel wall width; the DC group had a higher percentage of less than one-fourth of bowel wall than that of the KP or Fleet group (both p < 0.0167). DC, KP and Fleet have comparable barium sulfate coating efficiency in the sigmoid colon. However, in the hepatic flexure, the DC group had a higher percentage of barium sulfate coating without interruption than that of the KP or Fleet groups (both p < 0.0167). Conclusion: DC has a better barium sulfate coating efficiency in the hepatic flexure compared with KP and Fleet.
This study aimed to evaluate the effects of fogging on the effectiveness of a lead glass shield in protecting an operator from radiation exposure during conventional coronary angiography (CAG). Optically stimulated luminescence dosimeters (OSLDs) were used to measure the effects of fogged lead glass shields (FLSs) and clear lead glass shields (CLSs) on the radiation doses of a cardiac catheterization surgeon. We simulated the scatter radiation incident on the operator with five angiographic projections with 10-s exposures. Experiments were conducted with a field of view of 25 cm, maximum of 100 cm between the X-ray tube and image intensifier, and 80 cm between the image intensifier and operator. Lead glass fogging had no significant effect at any angiographic projection. The average dose at the lens of the eye, thyroid glands, and gonads did not differ significantly between FLS and CLS. Although most surgeons view ceiling-suspended shields as hindrances during surgical procedures, the radiation dose at the operator’s eyes and thyroid glands increased by 13 and 10 times without the shield. The fogging of the shield is probably caused by post-surgery UV decontamination or detergents. An operator has no cause for concern regarding the radiation protection afforded by an FLS during CAG procedures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.