Recombinant bacterial colonization plays an indispensable role in disease prevention, alleviation, and treatment. Successful application mainly depends on whether bacteria can efficiently spatiotemporally colonize the host gut. However, a primary limitation of existing methods is the lack of precise spatiotemporal regulation, resulting in uncontrolled methods that are less effective. Herein, we design upconversion microgels (UCMs) to convert near-infrared light (NIR) into blue light to activate recombinant light-responsive bacteria (Lresb) in vivo, where autocrine ''functional cellular glues'' made of adhesive proteins assist Lresb inefficiently colonizing the gut. The programmable engineering platform is further developed for the controlled and effective colonization of Escherichia coli Nissle 1917 (EcN) in the gut. The colonizing bacteria effectively alleviate DSS-induced colitis in mice. We anticipate that this approach could facilitate the clinical application of engineered microbial therapeutics to accurately and effectively regulate host health.
Digital polymerase chain reaction (PCR) plays important roles in the detection and quantification of nucleic acid targets, while there still remain challenges including high cost, complex operation, and low integration of the instrumental system. Here, in this work, a novel microfluidic chip based on co-flow step emulsification is proposed for droplet digital PCR (ddPCR), which can achieve droplet generation, droplet array self-assembly, PCR amplification, and fluorescence detection on a single device. With the combination of single-layer lithography and punching operation, a step microstructure was constructed and it served as the key element to develop a Laplace pressure gradient at the Rayleigh–Plateau instability interface so as to achieve droplet generation. It is demonstrated that the fabrication of step microstructure is low cost, easy-to-operate, and reliable. In addition, the single droplet volume can be adjusted flexibly due to the co-flow design; thus, the ddPCR chip can get an ultrahigh upper limit of quantification to deal with DNA templates with high concentrations. Furthermore, the volume fraction of the resulting droplets in this ddPCR chip can be up to 72% and it results in closely spaced droplet arrays, makes the best of CCD camera for fluorescence detections, and is beneficial for the minimization of a ddPCR system. The quantitative capability of the ddPCR chip was evaluated by measuring template DNA at concentrations from 20 to 50 000 copies/μL. Owing to the characteristics of low cost, easy operation, excellent quantitative capability, and minimization, the proposed ddPCR chip meets the requirements of DNA molecule quantification and is expected to be applied in the point-of-care testing field.
As a platform to mix the bioagents (i.e. serum, urine), we take advantage of the alternating current electrothermal (ACET) effect which is quite suitable for rapid pumping/mixing of high conductive biomicrofluids. Here we demonstrate the concept of a high-efficient mixing microfluidic chip as a basic unit to provide rapid mixing for lab-on-a-chip applications. As an active mixer, two streams are introduced into a ring-shape microchamber by a passive flow rate regulator, and then the microfluids in the chamber are actuated by a nonuniform electric field with a phase shift of 180°. It shows perfect mixing performance by arranging four arc-electrodes around the ring-shape microchamber subsequently. Taking the Joule heating and conductivity/permittivity changes into consideration, a temperature dependent fully coupled numerical model is presented. Then, the effects of applied voltages on mixing performance and temperature rise are provided to get an optimized design for ACET mixer. Moreover, the arrangement of the electrode array is analyzed to show the effects of electrode patterns on the swirls and mixing efficiencies. Since all the electrodes here are located along a ring-shape central microchamber, the ring-shape micromixer is quite suitable to function as a compact element modular for integrated microfluidic chips.
Droplet digital polymerase chain reaction (ddPCR) suffers from the need for specific equipment and skilled personnel; thus, we here present a chamber-based digital PCR microfluidic device that is compatible with fluorescence image read-out systems and removes bubbles by a pre-degassed microfluidic device that consists of a pilot channel and micro chamber arrays. Digitalized PCR reagents are introduced into micro chambers, and thermocycles are taken to perform a DNA amplification process. Then, fluorescence images of a micro chamber array are read out and analyzed to obtain the total number of positive chambers. Thereby, the copy numbers of target DNA are calculated for quantitative detections. As a validation, this device is evaluated by the application of meat authentication. We performed dPCR tests using DNA templates extracted from a pure mutton DNA template with different dilutions. Then, the dPCR chip was used to identify the meat authentication using mutton–chicken mixtures with different mass ratios, showing its performance in real biotechnical applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.