Background and Aims:The aim was to evaluate efficacy of optic nerve sheath diameter (ONSD) by ultrasound as a noninvasive method for detecting raised intracranial pressure (ICP) in intensive care unit, to compare with computed tomography/magnetic resonance imaging (MRI) findings of raised ICP and to prognosticate ONSD value with treatment.Materials and Methods:We conducted a prospective, observational study on 101 adults by including 41 healthy individuals in group A as control and 60 patients in group B admitted with fever, headache, vomiting, and altered sensorium. We examined them in supine position using 10 MHz linear array probe on closed eyelid. ONSD was measured 3 mm behind the globe in each eye. A mean binocular ONSD > 4.6 mm in female and 4.8 mm in male was considered abnormal. Midline shift, edema, effacement or ONSD > 5.0 mm on T2 MRI suggestive of elevated ICP was used to evaluate ONSD accuracy.Results:Group A mean ONSD was 4.6 mm in females and 4.8 mm in males. Group B mean ONSD for 17 females was 5.103 ± 0.6221 mm (P = 0.002) and for 43 males 5.081 ± 0.5799 mm (P = 0.032). Radiological sign of raised ICP was confirmed in 35 patients (females = 11 and males = 24) with high ONSD value. Sensitivity of detecting raised ICP by ONSD was 84.6% in females and 75% in males while specificity was 100% in both genders. Out of 25 patients without radiological signs of raised ICP 10 patients showed high ONSD (females = 4.735 mm and males = 4.907 mm). ONSD was well prognosticated with treatment modalities.Conclusion:Bedside ocular ultrasonography for measuring ONSD can be used an early test for diagnosing raised ICP as it is a noninvasive, cost effective bedside test, which can be repeated for re-evaluation.
Aim:Correlation of upper air column width ratio in postextubation stridor patients.Materials and Methods:A prospective observational study was conducted in a tertiary hospital between January and December 2013. Patients who were admitted in Intensive Care Unit and intubated for >24 h were included (72 patients). The upper airway air column width ratio (air column width before extubation/air column width after intubation) was calculated and compared in patient with or without postextubation stridor.Results:The incidence of stridor was 6.9% (5/72). The duration of mechanical ventilation was 5.60 ± 1.14 days and 3.91 ± 1.45 days in stridor and nonstridor group respectively. In all 5 patients who had stridor, the upper airway air column width ratio was 0.8 or less.Conclusion:Air column width ratio of 0.8 or less may be helpful in predicting postextubation stridor, which should be confirmed by large observational studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.