We describe the design of a surface-electrode ion trap junction, which is a key element for large-scale ion trap arrays. A bi-objective optimization method is used for designing the electrodes, which maintains the total pseudo-potential curvature while minimizing the axial pseudo-potential gradient along the ion transport path. To facilitate the laser beam delivery for parallel operations in multiple trap zones, we implemented integrated optics on each arm of this X-junction trap. The layout of the trap chip for commercial foundry fabrication is presented. This work suggests routes to improving ion trap junction performance in scalable implementations. Together with integrated optical addressing, this contributes to modular trapped-ion quantum computing in interconnected 2-dimensional arrays.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.