Implant-associated infections remain one of the main problems in the treatment of open tibia fractures. The role of systemic antibiotic prophylaxis is now agreed and accepted; nevertheless, recent literature also seems to emphasize the importance of local antibiotic therapy at the fracture site. Several therapeutic strategies have been proposed to overcome this new need. Antibiotic-coated nails play crucial role in this, allowing both infection prevention and favoring the fracture stabilization. We describe the outcome of patients with open diaphyseal tibia fracture treated either with a standard uncoated nail or a gentamicin-coated nail from January 2016 to December 2018 at our second level emergency-urgency department. Primary outcomes were infection rate and bone union rate. Other outcomes reported are reoperation rate, time between injury and nailing, and safety of antibiotic nail. Numerical variables were tabulated using mean, standard deviation, minimum, maximum, and number of observations. Categorical variables were tabulated using number of observations. 23 patients treated with uncoated nail and 23 patients treated with antibiotic-coated tibia nail were included in the study and were evaluated for a minimum follow-up of 18 months. Among the 46 patients, 9 were Gustilo-Anderson type I, 21 type II, and 16 type III open fracture. Regarding the bone healing rate at 12 months, 16 fractures in the first group and 18 in the second were completely healed. 4 infections were found in the first group (3 superficial surgical site infection and 1 osteomyelitis) and 3 superficial infections in the second one. No adverse events have been recorded with antibiotic-coated nails. In this unicentric retrospective study observed no deep wound infections and good fracture healing in the use of antibiotic-coated nails. Antibiotic nails have been shown to play a role in the treatment of fractures in critically ill patients with severe soft tissue damage.
Implant-associated infections still represent one of the main problems in treatment of open fracture. The role of systemic antibiotic prophylaxis is now agreed and accepted; however, recent literature seems to underline the importance of local antibiotic therapy at the fracture site, and antibiotic nails have been shown to play a role in the treatment of open fractures in terms of fracture healing and lower risk of infection. We retrospectively analyzed our results, from January 2016 to March 2020, with the use of coated nails in the treatment of open tibial fractures, evaluating the rates of infection and fracture healing as primary outcomes and the rate of reoperations, time from trauma to nailing and hospital stay as secondary outcomes. Thirty-eight patients treated with coated nail (ETN ProtectTM, Synthes) were included in the study. Minimum follow-up was of 18 months. Thirty-four of 38 patients achieved bone union and 2 patients underwent septic non-union. In our series, no systemic toxicity or local hypersensitivity to antibiotics were recorded. From this study, use of antibiotic-coated nails appears to be a valid and safe option for treatment of open tibial fractures and prevention of implant-related infections, particularly in tibial fractures with severe soft tissue exposure and impairment.
Background: Femoral shaft fractures (FSFs) are a frequent injury in traumatology for which intramedullary nailing (IMN) is considered the gold standard treatment. Nonunion (NU) is one of the most frequent complications in FSF treated with IMN, with a percentage from 1.1% to 14%. Plate augmentation (PA), the addition of a compression plate and screws, with or without bone graft has been described as an effective option for the treatment of NU, improving the biomechanical conditions at the fracture site. The aim of this review was to analyze the literature relating to the use of PA in NU after IMN in FSFs to assess the efficacy of the technique. Methods: An electronic search on PubMed, Google Scholar, and Web of Science was conducted to search for all studies concerning PA of femoral shaft NUs after IMN. Results: Twenty-four studies were included in the review comprising a total of 502 patients with a mean age of 39.5 years. Of these, 200 hundred patients had atrophic pseudoarthrosis and 123 had hypertrophic pseudoarthrosis, while in 179, the type of pseudoarthrosis was not reported. The most frequently used plate for PA was the dynamic compression plate (DCP); in 87.1% of the cases, the authors added a bone graft to the plate fixation. In 98.0% of the patients, a complete bone union was achieved in a mean time of 5.8 ± 2.12 months. Conclusion: The patients treated with PA included in this review showed a good rate of consolidation in the femoral shaft NUs, with good functional recovery and a low incidence of complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.