Orbital volume evaluation is an important part of pre-operative assessments in orbital trauma and congenital deformity patients. The availability of the affordable, open-source software, OsiriX, as a tool for preoperative planning increased the popularity of radiological assessments by the surgeon. A volume calculation method based on 3D volume rendering-assisted region-of-interest computation was used to determine the normal orbital volume in Taiwanese patients after reorientation to the Frankfurt plane. Method one utilized 3D points for intuitive orbital rim outlining. The mean normal orbital volume for left and right orbits was 24.3±1.51 ml and 24.7±1.17 ml in male and 21.0±1.21 ml and 21.1±1.30 ml in female subjects. Another method (method two) based on the bilateral orbital lateral rim was also used to calculate orbital volume and compared with method one. The mean normal orbital volume for left and right orbits was 19.0±1.68 ml and 19.1±1.45 ml in male and 16.0±1.01 ml and 16.1±0.92 ml in female subjects. The inter-rater reliability and intra-rater measurement accuracy between users for both methods was found to be acceptable for orbital volume calculations. 3D-assisted quantification of orbital volume is a feasible technique for orbital volume assessment. The normal orbital volume can be used as controls in cases of unilateral orbital reconstruction with a mean size discrepancy of less than 3.1±2.03% in females and 2.7±1.32% in males. The OsiriX software can be used reliably by the individual surgeon as a comprehensive preoperative planning and imaging tool for orbital volume measurement and computed tomography reorientation.
A new, to our knowledge, design method for diffractive optical elements (DOE's) is described and compared with existing methods. The technique applies a nonlinear least-squares algorithm to design two-dimensional pure phase DOE's that reconstruct a desired diffraction pattern with high uniformity, efficiency, and signal-to-noise ratio. The technique also uses a phase-shifting quantization procedure that greatly reduces the quantization error for DOE's to a minimum level. In this paper, we compare simulated reconstruction results of DOE's designed by use of these methods with results obtained by the commonly used two-stage iterative Fourier transform design algorithm of Wyrowski. [J. Opt. Soc. Am. A 7, 961, (1990)].
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.