A new simple, rapid stability indicating assay method has been developed and validated for the determination of emtricitabine, tenofovir disoproxil fumarate, elvitegravir and cobicistat using reverse-phase high-performance liquid chromatography in their pharmaceutical dosage form. The chromatographic separation was performed on an ODS column (250 × 4.6 mm, 5 µm) using mobile phase A (potassium dihydrogen orthophosphate, pH adjusted to 2.5) and mobile phase B (acetonitrile) in the ratio of 55:45% v/v at a flow rate of 1 mL/min. The analytes were detected at 250 nm. The method was found to be linear in the concentration range of 2-12 µg/mL for EMT, 3-18 µg/mL for TNDF, 1.5-9 µg/mL for ELV and COB, with the coefficient value (R(2)) of >0.9990. The accuracy was measured via recovery studies and found to be acceptable, and the percentage recoveries were found in the range of 99.93-100.08 ± 0.5%. Forced degradation studies were also conducted, and the drugs were subjected to various stress conditions such as acid hydrolysis, base hydrolysis, oxidative, photolytic and thermal degradation. The proposed method was successfully validated and applied for the quantitative estimation of these drugs in both bulk and tablet dosage forms.
The present study describes the stability indicating RP-HPLC method for simultaneous estimation of aliskiren hemifumarate and amlodipine besylate in pharmaceutical dosage forms. The proposed RP-HPLC method was developed by using waters 2695 separation module equipped with PDA detector and chromatographic separation was carried on C-8 Inertsil ODS (150 × 4.6 mm, 5 ) column at a flow rate of 1 mL/min and the run time is 10 min. The mobile phase consisted of phosphate buffer and acetonitrile in the ratio of 40 : 60% v/v and pH was adjusted to 3 with orthophosphoric acid and eluents were scanned using PDA detector at 237 nm. The retention time of aliskiren and amlodipine was found to be 3.98 and 5.14 min, respectively. A linearity response was observed in the concentration range of 30-225 g/mL for aliskiren and 2-15 g/mL for amlodipine, respectively. Limit of detection and limit of quantification for aliskiren are 0.161 g/mL and 0.489 g/mL and for amlodipine are 0.133 g/mL and 0.404 g/mL, respectively. The stability indicating method was developed by subjecting the drugs to stress conditions such as acid and base hydrolysis, oxidation, and photo-and thermal degradation and the degraded products formed were resolved successfully from the samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.