The rapid and accurate detection of carbapenemase-producing (CPE) is necessary for patient management and infection control measures. We compared the performance of the BD Phoenix CPO Detect with that of a homemade Carba NP assay and a modified carbapenem inactivation method (mCIM) by challenging all 3 assays with 190 isolates of with meropenem MICs of >0.125 mg/liter. A total of 160 isolates produced KPC-, IMI-1-, NDM-, IMP-, and OXA-type carbapenemases, while 30 isolates were negative for carbapenemase production. The sensitivity and specificity were 90.6% (95% confidence interval [CI], 85.0% to 94.7%) and 100.0% (95% CI, 88.4% to 100.0%), respectively, for the Carba NP; 100.0% (95% CI, 97.7% to 100.0%) and 96.7% (95% CI, 82.7% to 99.9%), respectively, for the mCIM; and 89.4% (95% CI, 83.5% to 93.7%) and 66.7% (95% CI, 47.2% to 82.7%), respectively, for the BD Phoenix CPO Detect. In particular, the BD CPO Detect failed to detect a significant number of CPE with IMI-1. While the BD Phoenix CPO Detect is able to classify carbapenemases and is built into routine susceptibility testing with the potential to reduce the time to CPE detection, its low specificity means that a positive result will need confirmatory testing by another method.
Objectives: To determine if using alternative streaking patterns on the BD Kiestra InoqulA can impact colony isolation and improve turnaround time (TAT) of methicillin-resistant Staphylococcus aureus (MRSA) and carbapenem-resistant Enterobacterales (CRE) screening samples. Methods: A total of 1571 positive MRSA screening samples were studied, of which 755 screening plates were streaked by the standard pattern (4-Quadrant uniform S200) and 816 plates were streaked by an alternative pattern (Zigzag 3.5e1 S200). A total of 424 CRE-positive screening samples were studied, of which 211 screening plates were streaked by the standard pattern (Zigzag 2.5e1 inoc S200) and 213 plates were streaked by an alternative customized pattern (Zigzag 3.5e1 vertstreak s200). Results: There was a reduction in the number of MRSA screening plates with insufficient isolated colonies for confirmatory testing from 75 plates (9.9%) when using the standard pattern to 18 plates (2.2%) when using the alternative streaking pattern. MRSA cases with a TAT above 36 hours also reduced significantly from 144 (19.1%) to 20 (2.4%). The number of CRE screening plates with insufficient colonies for same-day confirmatory testing reduced from 16 (7.6%) when using the standard pattern to two plates (1.1%) when using the alternative customized pattern. CRE cases with a TAT above 36 hours also reduced from 16 (7.6%) to seven (3.3%). Conclusions: The change in streaking patterns resulted in more plates with sufficient isolated colonies as well as reduced man-hours and materials required to perform subculture of mixed colonies and overall improvements in TAT.
Background Computerisation of various processes in hospitals and reliance on electronic devices raises the concern of contamination of these devices from the patient environment. We undertook this study to determine if an attached hand hygiene device that unlocks the screen of a computer on wheels (COW) on usage can be effective in decreasing the microbiological burden on computer keyboards. Methods An electronic hand sanitizer was integrated onto the COW. A prospective cohort study with a crossover design involving 2 control and 2 intervention wards was used. The study end point was the number of colony forming units found on the keyboards. Bacteria were classified into 4 main groups; pathogenic, skin flora, from the environment or those thought to be commensals in healthy individuals. We then used a mixed effects model for the statistical analysis to determine if there were any differences before and after the intervention. Results Thirty-nine keyboards were swabbed at baseline, day 7 and 14, with 234 keyboards cultured, colony forming units (CFUs) counted and organisms isolated. By mixed model analysis, the difference of mean bacteria count between intervention and control for week 1 was 32.74 (− 32.74, CI − 94.29 to 28.75, p = 0.29), for week 2 by 155.86 (− 155.86, CI − 227.45 to − 83.53, p < 0.0001), and after the 2-week period by 157.04 (− 157.04, CI − 231.53 to − 82.67, p < 0.0001). In the sub-analysis, there were significant differences of pathogenic bacteria counts for the Intervention as compared to the Control in contrast with commensal counts. Conclusion A hand hygiene device attached to a COW may be effective in decreasing the microbiological burden on computer keyboards.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.