PurposeA feasibility study of 3D volume-based interstitial brachytherapy using thermoplastic polyether ether ketone (PEEK) catheters in advanced cervical cancer MR-based brachytherapy, when MR-compatible applicators are not available.Material and methodsFive cervical cancer patients received EBRT dose of 50 Gy in 25 fractions to whole pelvis using 3D conformal radiotherapy after standard pre-treatment evaluation. In our institute, interstitial brachytherapy (ISBT) is planned in BrachyVision TPS and routinely performed using stainless steel needles with Syed-Neblett template. Standard MR-compatible ISBT applicators were not available; therefore, the implant was carried out using PEEK catheters and Syed-Neblett template. The T1 and T2 MR and CT images of patients were acquired for treatment planning. Gross tumor volume (GTV), high-risk clinical target volume (HR-CTV), intermediate-risk clinical target volume (IR-CTV), and organs at risk (OARs) were delineated with the use of MR T2 weighted images, following GEC-ESTRO guidelines. Volumetric optimization was used for planning, and the treatment plan was executed with high-dose-rate (HDR) 192Ir Gammamed Plus device.ResultsThe dose prescribed to HR-CTV was 30 Gy low-dose-rate (LDR) equivalent (5 Gy × 4 fractions). Doses to target volume and OARs were analyzed using dose volume histogram (DVH). Dose values were biologically normalized to equivalent doses of 2 Gy fractions (EQD2). The average tumor volume was 67 cc and the average D90 of HR-CTV was 29 Gy (5.7 Gy/fraction) EQD2. D100 of HR-CTV volume was 18 Gy (3.8 Gy/fraction) EQD2. The total doses of 2 cc of rectum and bladder were 70 Gy and 76 Gy EQD2 (3.71 Gy and 4.04 Gy dose/fraction), respectively.ConclusionsWhen the facilities for MR-compatible applicators are not available, MR-based ISBT is feasible with PEEK catheters using available resources for advanced cervical cancer. Doses to HR-CTV and IR-CTV were achieved, restricting doses to OARs as per GEC-ESTRO guidelines.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.